Energy and Compressed Air Supply Power supply S tudent Guide (FSE) SI PL ACE X Series and X4I Energy and Compres sed Air Supply Edition 01/20 09 EN 172 5.2 Power supply 5-2: Main power supply unit Legend 1 DC/DC Converte…

Energy and Compressed Air Supply
Overview
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Energy and Compressed Air Supply
171
5 Energy and Compressed Air Supply
5.1 Overview
The diagram below shows where the energy supplying and distributing components for system operation
are installed:
5-1: Main components
Legend:
1 Power supply 3 Pneumatic Unit
2 Sector distributor for sector 2 4 Sector distributor for sector 4
T Transport direction

Energy and Compressed Air Supply
Power supply
Student Guide (FSE) SIPLACE X Series and X4I
Energy and Compressed Air Supply Edition 01/2009 EN
172
5.2 Power supply
5-2: Main power supply unit
Legend
1 DC/DC Converter 24 V 7 Transformer T2
2 DC/DC Converter 5 V and additional 24V 8 Transformer T1
3 Protective contactor combination K6 (SSK) 9 Fuse F61 – Fuse F142
4 Fuse F5 (10A) for star axis 10 Main distributor voltage supply
5 Fuse F11(1A) for transformer inrush current
limitation board
11 Inrush current limitation board
a: Transformer: EST
b: Servo: Ess
6 Discharge inductor L20

Energy and Compressed Air Supply
Naming Convention of Connectors and Cables Power supply
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Energy and Compressed Air Supply
173
5.2.1 Naming Convention of Connectors and Cables
The wiring on the SIPLACE X is highly structured. Every cable, connection or distributor uses an exact
term, which refers to the sections and units in question:
Sector 2: term q+
Main-distributor section 2: Designation X1qa, X2qa, X3qa, ...
CAN I/O module (A1): Designation X1qb, X2qb, X3qb, ...
Vision DC/DC converter (A3): Designation X1qc, X2qc, X3qc, ...
Vision control module (A4): Designation X1qd, X2qd, X3qd, ...
Circuit board 8-fold AND operation (A5): Designation X1qe, X2qe and X3qe
Sector 4: term r+
Sub-distributor section 4: Designation X1ra, X2ra, X3ra, ...
CAN I/O module (A1): Designation X1rb, X2rb, X3rb, ...
Vision DC/DC converter (A3): Designation X1rc, X2rc, X3rc, ...
Vision control module (A4): Designation X1rd, X2rd, X3rd, ...
Circuit board 8-fold AND operation (A5): Designation X1re, X2re and X3re
Handing over constituent (A2): Designation X30ra and X31ra
Placement head gantry 1: Designation a+
Gantry distributor: 00 353593 aa
Gantry interface: 00 363330 ab
Head interface: 03000900 ac
Vision board: 03 321469 au
Placement head gantry 3: Designation b+ / c+
(in machines up to MA No. xx the designation is b+ /
in machines from MA No. xx the designation is c+)
Gantry distributor: 00 353593 ba
Gantry interface: 00 363330 bb
Head interface: 03000900 bc
Vision board: 03 321469 bu
Placement head gantry 4: Designation d+
Gantry distributor: 00 353593 da
Gantry interface: 00 363330 db
Head interface: 03000900 dc;
Vision board: 03 321469 du;
Computer unit: X1p+