Energy and Compressed Air Supply
Naming Convention of Connectors and Cables Power supply
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Energy and Compressed Air Supply
173
5.2.1 Naming Convention of Connectors and Cables
The wiring on the SIPLACE X is highly structured. Every cable, connection or distributor uses an exact
term, which refers to the sections and units in question:
Sector 2: term q+
Main-distributor section 2: Designation X1qa, X2qa, X3qa, ...
CAN I/O module (A1): Designation X1qb, X2qb, X3qb, ...
Vision DC/DC converter (A3): Designation X1qc, X2qc, X3qc, ...
Vision control module (A4): Designation X1qd, X2qd, X3qd, ...
Circuit board 8-fold AND operation (A5): Designation X1qe, X2qe and X3qe
Sector 4: term r+
Sub-distributor section 4: Designation X1ra, X2ra, X3ra, ...
CAN I/O module (A1): Designation X1rb, X2rb, X3rb, ...
Vision DC/DC converter (A3): Designation X1rc, X2rc, X3rc, ...
Vision control module (A4): Designation X1rd, X2rd, X3rd, ...
Circuit board 8-fold AND operation (A5): Designation X1re, X2re and X3re
Handing over constituent (A2): Designation X30ra and X31ra
Placement head gantry 1: Designation a+
Gantry distributor: 00 353593 aa
Gantry interface: 00 363330 ab
Head interface: 03000900 ac
Vision board: 03 321469 au
Placement head gantry 3: Designation b+ / c+
(in machines up to MA No. xx the designation is b+ /
in machines from MA No. xx the designation is c+)
Gantry distributor: 00 353593 ba
Gantry interface: 00 363330 bb
Head interface: 03000900 bc
Vision board: 03 321469 bu
Placement head gantry 4: Designation d+
Gantry distributor: 00 353593 da
Gantry interface: 00 363330 db
Head interface: 03000900 dc;
Vision board: 03 321469 du;
Computer unit: X1p+
Energy and Compressed Air Supply
Power supply Main distributor (X series from Ma. No. B326)
Student Guide (FSE) SIPLACE X Series and X4I
Energy and Compressed Air Supply Edition 01/2009 EN
174
5.2.2 Main distributor (X series from Ma. No. B326)
5-3: Main distributor (X series from Ma. No. B326, X4I) [03046225-xx]
Legend:
1. Terminal strip X1qa (GND, +5 V, +15 V, -15 V,
+24 V, various signals)
2. DC/DC converter for illumination of all
cameras (PCB, component and stationary
cameras) in placement area 2
3. Socket for Interface 1-Wire CAT5
4. CAN-Bus I/O module (A1)
5. Connector block (connection X2qa - X6qa,
X71qa - X74qa and X9qa - X24qa)
6. Relay K2 switches the compressed air supply
for the placement heads off (can be configured
in the station software)
Energy and Compressed Air Supply
Subdistributor (X series from Ma No. B326) Power supply
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Energy and Compressed Air Supply
175
5.2.3 Subdistributor (X series from Ma No. B326)
5.2.4 Power supply
The main power supply unit is mounted on a compact slide-in module, and located on the left side of the
machine. When viewed from the outside only the red main power switch is visible.
A lockable door prevents access to the power supply.
With the open cover, the state of the following protective devices can be quite easily monitored.
Motor Circuit Breaker
Main contactor
Safety relay
Power circuit breaker
Protective contactor combination (SSK)
5-4: Subdistributor (X series from Ma No. B326, X4I) [03046226-xx]
Legend:
1. Terminal strip X1ra (GND,+5 V,+15 V,-
15 V,+24 V,+52 V, various signals)
2. DC/DC distributor for illumination of all
cameras (PCB, component and stationary
cameras) in placement area 1
3. Socket for Interface 1-Wire CAT5
4. CAN I/O module (A1)
5. Connector block (connection X3ra - X6ra,
X71ra-X74ra, X10ra - X24ra)
6. F1: Fuse for the hood fan
7. K3: Relay for hood fan
8. K1: This relay switches the main valve in the
pneumatic unit.