00196044-05 - sg x und x4i fse_en - 第252页
C&P20A Overview Compressed Air Supply to the C&P20A S tudent Guide (FSE) SI PL ACE X Series and X4I C&P20A Edition 01/2009 EN 252 7.2.5.2 Overview of V acuum Supply 7-7: General overview of the vacuum functio…

C&P20A
Compressed Air Supply to the C&P20A Overview
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN C&P20A
251
7.2.5.1 Overview of Air Blast Supply
7-6: General overview of the air blast function
Legend
RED Vacuum 1 Smoothed distributor disc [03008286-0X]
BLUE Compressed air (air blast)

C&P20A
Overview Compressed Air Supply to the C&P20A
Student Guide (FSE) SIPLACE X Series and X4I
C&P20A Edition 01/2009 EN
252
7.2.5.2 Overview of Vacuum Supply
7-7: General overview of the vacuum function
Legend
RED Vacuum BLUE Compressed air (air blast)

C&P20A
Compressed Air Supply to the C&P20A Reference Run for C&P20A Head
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN C&P20A
253
7.3 Reference Run for C&P20A Head
7-8: Reference run for C&P20 head
The C&P20 head has 22 axes: the Z axis, the star
axis and 20 independently working DP axes, plus
the X and Y axes for the gantry. Before starting
production, all axes must be initialized, so that the
axis controller can locate their actual mechanical
positions. The software start procedure first loads
the DP master firmware and then rotates the DP
axes into the 0° position.
General Procedure
The reference run for the individual axes can
be optimized so that the X, Y, star and all DP
axes visibly start at the same time. As can be
seen in the flow chart, only the Z axis is moved
as the last axis.