00196044-05 - sg x und x4i fse_en - 第453页
Modular Conveyor Setting the Fixed Conveyor Side (from SW701) Conveyor Settings S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Modular Conveyor 453 Example of X series 11-11: Setting the "fixed co…

Modular Conveyor
Conveyor Settings Setting the Fixed Conveyor Side (from SW701)
Student Guide (FSE) SIPLACE X Series and X4I
Modular Conveyor Edition 01/2009 EN
452
11.3.2 Setting the Fixed Conveyor Side (from SW701)
11.3.2.1 General Notes
Setting the fixed conveyor side
The fixed conveyor side is always set in the standard mode with right side fixed. You need to set a value
of 38.8 mm between the conveyor base and the fixed conveyor side, with the help of a gauge.
03054247-xx: Gauge for fixed conveyor side DT/ET HS60/D4
03054248-xx: Distance gauge for conveyor side DT HS-60/D4
Teach the fixed side with the software and store the value.
11-10: Setting the fixed conveyor side
Values
The measurement is performed between the side flange and the fitting flange of the mounting frame.
(See also "Example for X Series")
When using dual conveyors in the X4I, the fixed
conveyor side can be set as required i.e. the left or
right side, or the outer edges of each conveyor for
i-placement. The compatibility to the other
machines can be set via predefined values in the
SW (see diagram).
NOTE:
This menu is available from user level
Service (customer)
!
Machine Single conveyor
Standard width
508 (460) mm
Dual conveyor
Standard width
250 (216) mm
Quad lane
Standard width
114 mm
HF series 19 (43) mm 4.5 (38.8) mm
X series / D3
up to July 2007
19 (43) mm 4.5 (38.8) mm
X series / D3
from July 2007
16 (40) mm 4.5 (38.8) mm 2 mm
X4I 16 (40) mm 4.5 (38.8) mm 2 mm

Modular Conveyor
Setting the Fixed Conveyor Side (from SW701) Conveyor Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Modular Conveyor
453
Example of X series
11-11: Setting the "fixed conveyor side" in SIPLACE X, HF series
Shaft fixtures (bearing flange)
Machine Single conveyor
Standard width
460 mm
Dual conveyor
Standard width
216 mm
HS-60 34.5 mm 30.5 mm
S27 HM 34.5 mm 30.5 mm
D4 34.5 mm 30.5 mm
D1/D2 34.5 mm 30.5 mm
NOTE:
The fixed conveyor side should be adjusted only with the SITEST software and the width
adjustment devices. This ensures that the conveyor sides are in their correct positions (parallel)
i.e. that the conveyor runs straight.
NOTE:
Since July 2007, X machines with single conveyors use a new version of the shaft fixtures
(bearing flange) with a width of 15 mm, instead of 12 mm. The setting for standard single
conveyors changes with this new version, to 40 mm.

Modular Conveyor
Conveyor Settings Setting the Fixed Conveyor Side (from SW701)
Student Guide (FSE) SIPLACE X Series and X4I
Modular Conveyor Edition 01/2009 EN
454
Legend
After teaching the fixed conveyor side, you need to recalibrate the PCB reference corner, to prevent
fiducial errors during placement.
11.3.2.2 Connecting the Dual Conveyor Lifting Tables
X Remove the lifting table plate on conveyor lane 2 in PA1 and on lane 1 in PA2.
X Loosen the lockscrew(s) (4) and use a screwdriver to push the hexagonal circlip over the shaft on
lifting table 1.
X Perform lifting table connection for all placement areas (arrangement rotated by 180°.)
X Configure the new conveyor mode in SIPLACE Pro
(1) Bearing flange – first version 12 mm (2) Bearing flange – new version 15 mm
NOTE:
The fixed conveyor side may only be adjusted via software and with the width adjustment
devices. This ensures that the conveyor sides are in their correct positions (parallel) i.e. that the
conveyor runs straight.
NOTE:
This option is a mechanical necessity when you use the dual conveyor as a single conveyor.
The two lifting tables move parallel when they are connected.
11-12: Lifting table
The drive shaft (1) is connected to the piston
rod of the pneumatic cylinder. This shaft
couple the second lifting table of the dual
conveyor. The lifting table drive shaft also has
an additional rod with a hexagonal circlip.
They secure the sleeve shaft in the desired
position.
Direction of transport (2).
Direction (3) in which the hollow shaft from
lifting table 2 (1 in PA 2) is to be moved to lifting
table 1 (2 in PA 2).
Lock screws (4).