Modular Conveyor Conveyor Control TSP 301 Conveyor Settings S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Modular Conveyor 465 1 1.3.10.2 Conveyor Control TSP 301 with Siemens Interface 11-25: TSP 301…

Modular Conveyor
Conveyor Settings Conveyor Control TSP 301
Student Guide (FSE) SIPLACE X Series and X4I
Modular Conveyor Edition 01/2009 EN
464
11.3.10 Conveyor Control TSP 301
11.3.10.1 Jumper Settings for TSP 301
*Switches 1-2 set the hardware ID 5 for D4 machines and hardware ID 6 for X machines, HF and D3.
11-23: Jumper positions for conveyor control TSP 301
Legend
1. J7 CAN bus 1 terminating resistor
2. F6 Main Fuse TSP 301
3. F1 - F5 Fuses for the conveyor motors
4. J3 interference loop
5. J6 CAN bus 2 terminating resistor (not used)
6. J2, J1 downstream/upstream station
7. S4 DIL switch
11-24: Jumper J1, J2 "downstream/upstream station" at TSP 301
Legend
J1 upstream station
J2 downstream station
J3 interference loop (emergency stop on
productivity lift switches the placement
machine off)
J6 CAN bus 2 terminating resistor (not used)
J7 CAN bus 1 terminating resistor
S X4I D4 X/D3/HF Comments
1ON ON ONON*
2OFF ON OFF ON* = SIPLACE D4, OFF: SIPLACE X, HF, D3
3OFF OFF OFF OFF= clamping sensor is no longer used
4ONOFFOFFON = X4I, OFF: SIPLACE D4, X, HF, D3
5OFF OFF OFF Not in use
6 OFF ON OFF OFF OFF: Standard conveyor, ON: Quad lane
7OFF OFF OFF Not in use
8OFF OFF OFF Not in use

Modular Conveyor
Conveyor Control TSP 301 Conveyor Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Modular Conveyor
465
11.3.10.2 Conveyor Control TSP 301 with Siemens Interface
11-25: TSP 301 SMEMA --> Siemens
Legend
1. 10-pin plug for SMEMA interface
X3: upstream station
X4: downstream station
2. Connection for Siemens interface
X1: upstream station
X2: downstream station
NOTE: Standard / option
The SMEMA interface is the standard
and the Siemens interface optional for
all X machines.
The Siemens interface is the standard
and the SMEMA interface optional for
all D machines. An adapter is required
for the SMEMA interface when used on
D1/2/4 machines.
WARNING: Irreparable damage to the
TSP board!
The 10 pin Locking clip plug of SMEMA
connections must be disconnected
from the TSP 301!
Application: no modification.
Following modification are necessary for using the
Siemens interface:
X JumperJ1 / J2: need to be moved (see
following diagram).
X Disconnect the connector X3 and X4 on the
TSP 301!
X Connect the Siemens interface cable on the
connector X1 and X2.
11-26: Jumper J1 and J2 (Siemens/SMEMA)

Modular Conveyor
Conveyor Settings Conveyor Control TSP 301
Student Guide (FSE) SIPLACE X Series and X4I
Modular Conveyor Edition 01/2009 EN
466
11.3.10.3 LED Display on Conveyor Control TSP 301
11.3.10.4 Assignment Table: LEDs on the TSP 301 Conveyor Control
11-27: Conveyor Control TSP 301
Legend
1. Connector Siemens PCB handling interface
upstream station lane 1 with corresponding
LEDs PCB handling
2. Connector Siemens PCB handling interface
upstream station lane 1 with corresponding
LEDs PCB handling
The connector "Siemens PCB handling interface
for the upstream station of lane 2 with
corresponding LEDs for PCB handling" and the
connector "PCB handling interface for the
downstream station of lane 2 with corresponding
LEDs for PCB handling" are located on the
extension board (similar layout).
Anzeige
/Display
I / O LED assignment
H1 / F1-F5 Fuse F1-F5, Power supply 40 V
H2 / F6 Fuse F6 Power supply 24V
H4(ao) Initializing / control error
H5(ao) CAN bus 1, active
H6(ao) Flashing: Program running
H7(ao) CAN bus 2, active (optional)
H9 Out Interference loop
H14 IN Siemens interface for upstream station
H15 IN Siemens interface for downstream station
H20 IN Lifting table, placement area 1: Fork light barrier A
H21 IN Lifting table, placement area 1: Fork light barrier B
H22 IN Lifting table, placement area 2: Fork light barrier A