00196044-05 - sg x und x4i fse_en - 第477页

Calibration Calibration in General / C&P and CPP Calibration of Entire Machine S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Calibration 481 Requirements for calibration X Switch the machine on. X…

100%1 / 632
Calibration
Calibration of Entire Machine Calibration Position – Conveyor, Nozzle Changer, Nozzle Changer Station
Student Guide (FSE) SIPLACE X Series and X4I
Calibration Edition 01/2009 EN
480
12.2.4 Calibration Position – Conveyor, Nozzle Changer, Nozzle Changer Station
12.3 Calibration of Entire Machine
Tools
Calibration component
version SST 23 C&P20A [03034148-01]
version III non transparent HF/X – for CPP and Twin Head [03010565-01]
Nozzle type
for C&P20A: 1235
for Twin Head: 517, 528
for CPP: 2057
Board for calibrating the PCB conveyor width
Mapping plate (optional)
Legend
1. Two fiducials for each nozzle station
2. Two fiducials for each nozzle magazine
3. Each conveyor side has a fiducial which can
be used to determine the PCB reference
corner, based on the conveyor configuration.
DANGER: Risk of damage!
The gantry may move during some of the following procedures.
X Make sure that there are no objects in the travel range.
Calibration
Calibration in General / C&P and CPP Calibration of Entire Machine
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Calibration
481
Requirements for calibration
X Switch the machine on.
X Switch the user level to at least
Service (customer)
.
X Perform an overall reference run.
X Use the nozzle changer to help you configure the heads to be calibrated with the calibration nozzles.
X Place the calibration tools into the calibration tool pockets.
12.3.1 Calibration in General / C&P and CPP
12-2: General sequence to calibrate the machine
NOTE:
Before you place the calibration tool, make sure that it is clean. Also, be sure that you insert it
into the "calibration pocket" with its print of the fiducial structure on the bottom.
Calibration
Calibration of Entire Machine Calibration in General / Twin Head
Student Guide (FSE) SIPLACE X Series and X4I
Calibration Edition 01/2009 EN
482
12.3.2 Calibration in General / Twin Head
12-3: General sequence to calibrate the machine