00196044-05 - sg x und x4i fse_en - 第585页

MTC2 Adjustments feed axes MTC2 Calibration and Settings S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN MTC2 589 14.3.4 Adju stment s feed axes 14-52: Overview of the feed axes (cover plates and bel t …

100%1 / 632
MTC2
MTC2 Calibration and Settings Adjustments Lifting Axes
Student Guide (FSE) SIPLACE X Series and X4I
MTC2 Edition 01/2009 EN
588
14.3.3.3 Cassette guide rails
Tools and Equipment
1 set of Allen keys
Preparations
X Empty the MTC2 completely (see the User Manual).
X Prepare an empty cassette XL.
Setting the cassette guide rails
X Move the lifting axis into the refill position for cassette 1-> check the zero offset.
X Loosen the securing screws on both cassette guide rails.
X Tighten the securing screws of the inner cassette guide rail at the position in which the cassette can
still be inserted into the tower smoothly.
X Position the second cassette guide rail by means of the cassette parallel to the first cassette, so that
the cassette can be moved easily but without any lateral play. Tighten the securing screws here as
well.
X Check the setting of the other refill positions. -> "Check the refill positions“). If necessary, correct the
position of the cassette guide rails which has been set.
NOTE:
An empty cassette is needed to set the cassette guide rails.
14-51: Setting the cassette guide rails
Legend
1. Cassette XL in the refill position for tower 1
2. Cassette in the refill position for tower 2
3. Cassette guide rails for tower 1
4. Cassette guide rails for tower 2
MTC2
Adjustments feed axes MTC2 Calibration and Settings
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN MTC2
589
14.3.4 Adjustments feed axes
14-52: Overview of the feed axes (cover plates and belt covers removed)
Legend
1 Feed axis, tower 1 5 Toothed belt
2 Feed axis, tower 2 6 Disengaging mechanisms
3 Servo motors of the feed axes 7 Driver
4Drive belt
MTC2
MTC2 Calibration and Settings Adjustments feed axes
Student Guide (FSE) SIPLACE X Series and X4I
MTC2 Edition 01/2009 EN
590
14.3.4.1 Belt tension
Tools and Equipment
Belt frequency measurement device (inductive)
2 belt tension strips
1 set of Allen keys
1 set of open-ended wrenches
14-53: Checking and setting the belt tension
Legend
Preparations
X Empty the MTC2 completely (see the User Manual).
X Undock the MTC2 from the SIPLACE station (see User Manual).
X Remove both cover plates between the rails of the feed axes.
Checking and Setting the Drive Belt
X Carry out the relevant preparations (see Section ( Preparations
J
584 ) ).
X Measure the belt tension with the belt frequency measuring device in the following way:
X Make the drive belt oscillate and measure the frequency in the middle of the sloping surface,
between the motor axis and the belt wheel (for the measuring point, seeSection ( Tools and Equip-
ment
J
584 ) ).
X You must set the belt tension if the measured frequency deviates from the nominal value (120 Hz ±
5 Hz):
1 Drive belt (shown here for tower 2) 6 Eccentric axle of toothed belt with clamping
screw and flats for setting (shown here for tower
1)
2 Motor mounting block with clamping screws
(shown here for tower 1)
7 Measuring point, toothed belt (shown here for
tower 1)
3 Adjustment screw, drive belt (shown here for
tower 1)
8 Outer deflection roll (shown here for tower 1)
4 Measuring point, drive belt (shown here for
tower 2)
9 Driver
5 Toothed belt (shown here for tower 1)