Overview Pneumatic Unit Over view of Components S tudent Guide (FSE) SIPL ACE X Series and X4I Edition 01/2009 EN Overview 59 3.2.2 Pneumatic Unit 3-10: Pneumatic unit as rack unit Legend The pneumatic unit is mounte d o…

100%1 / 632
Overview
Overview of Components Power supply
Student Guide (FSE) SIPLACE X Series and X4I
Overview Edition 01/2009 EN
58
3.2.1 Power supply
The main power supply unit is mounted on a compact rack unit and is located on the left in the middle
section of the machine. From outside, you can only see the red main switch.
A lockable door prevents access to the power supply.
3.2.1.1 Overview of Voltages in the Power Supply Unit
3-9: Power supply
Legend
1. Main switch
2. Cover on the power supply unit
3. Power supply unit
4. Bracket for the cable fixture
5. Mains connection cable
T = PCB transport direction
Overview
Pneumatic Unit Overview of Components
Student Guide (FSE) SIPLACE X Series and X4I
Edition 01/2009 EN Overview
59
3.2.2 Pneumatic Unit
3-10: Pneumatic unit as rack unit
Legend
The pneumatic unit is mounted on a compact rack unit and is located on the right in the middle section
of the machine. Unauthorized access to the unit is prevented by a locked door, which can be opened
with a machine key. The pneumatic unit includes all electrical connections for control/regulation of the
compressed air supply and the conveyor control. The conveyor control with the SMEMA (Siemens)
board interface is responsible for the transport of boards in the machine and for the transport from the
upstream and downstream station.
1 Pneumatic Unit 6 Manometer for bulkcase or nozzle changer DLM
2 Compressed air hose coupling 7 Manometer for gantries
3 Shutoff valve 8 Manometer for machine components (docking
unit, conveyor, cutter, NC C&P20)
4 Gap for compressed air hose 9 Conveyor control TSP301
5 Manometer for input pressure
WARNING:
NEVER disconnect compressed air lines while they are still pressurized. Risk of injury!
Overview
Overview of Components Pneumatic Unit
Student Guide (FSE) SIPLACE X Series and X4I
Overview Edition 01/2009 EN
60
3.2.2.1 Pneumatic Circuit For Cooling the Y Linear Motors in Placement Areas 1/2
An additional pneumatic circuit, supplied with ambient air, has been integrated to cool the Y linear
motors. The ambient air is sucked in via a filter, with the help of a fan motor and is distributed to the Y
motors. The compressed air then escapes through the sides of the Y motors.
3.2.2.2 Pneumatic Circuit For Cooling the X Linear Motors in Placement Areas 1/2
The X motors are cooled by the discharged air from the vacuum generator of the C&P20A head.
3.2.2.3 Compressed Air Distributor Block
The pneumatic unit is used to prepare and distribute the compressed air required in the machine. The
inlet pressure at the compressed air connection must be at least 5.0 bar.
The following pneumatic circuits are supplied with compressed air via the distributor block:
Gantries 1 - 4 (placement heads), vacuum generation: 5.0 bar
Conveyor system: 5.0 bar
Tape cutter for locations 1 - 4: 5.0 bar
Nozzle changer for locations 1 - 4: 5.0 bar
Feed-in units for the changeover tables: 5.0 bar
Bulkcase feeder for locations 1 - 4: 2.5 bar
Fine adjustment for the individual pneumatic circuits is performed directly at the pneumatic units, via the
adjustment valves.