00196449-04_UM_FCCS_digital_DE_EN - 第62页
3 Camera Calibration in SW 605.xx Stations 3.4 XML Report (SW 605.xx) 62 Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020 Parameter name Value of camera Comme…

3 Camera Calibration in SW 605.xx Stations
3.4 XML Report (SW 605.xx)
Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020 61
Fig.20: Excerpt from the FCCS…xml file
3.4.1 Parameter Entries
The XML files which are available at the (start) end of calibration have the following parameters:
CameraData_36_KL-U5-0003_Gantry1.xml is the report file for the camera data. This can be
read out of the camera EPROM, before starting calibration.
FCCS.. datum .zeit .xml is the results file for the camera data. This can be viewed in the camera
EPROM, after Field Camera Calibration Service (FCCS).
Parameter name Value of camera Comment
<?xml version="1.0" encoding="Win-
dows-1252" ?>
- <Sensor system version
="1.0"> Camera version
<General SensorSystemType ="29" Component camera type (here for C&P 6
placement head)
MaterialNumber ="3018637-02"
SerialNumber ="KL-U5-0013" /
>
Camera serial number ( also on the camera
label)
<Camera Type ="iX20-K01" CCD sensor type
Version ="VER 0002"
SerialNumber ="0055.10.06" />

3 Camera Calibration in SW 605.xx Stations
3.4 XML Report (SW 605.xx)
62 Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020
Parameter name Value of camera Comment
<Firmware Firmware versions which are "downloadable"
with SITEST
Application ="0.5.03.02"
BIOS ="0.5.03.CF" />
- <Calibration
FirstCalibration ="22.5.2006" Calibration date during manufacture
LastCalibration ="2006-10-25" State of current –, last calibration.
TypeOfLastCalibration ="20" 1 Brightness calibration for production / 20 –
calibration in the application on site
NumberOfCalibrations ="2"> Counter status of all complete calibrations
(saved in the camera EPROM)
<CameraPosition Position of stationary camera in X/Y machine
coordinate system
x_mm ="0.000"
y_mm ="0.000"
Angle_degrees ="-90.00" /> Camera angle in the machine
<FocusHeight
z_mm ="14,833" />
<Illumination Brightness values of illumination levels after
white balance
Plane1 ="123" Camera-specific illumination levels
> Values should be similar
> Threshold values depend on the camera.
See table in section 3.5
Plane2 ="126"
Plane3 ="117"
Plane4 ="140"
Plane5 ="129"
Plane6 ="0" Levels with ‘0’ are not available for the respect-
ive camera type.
CameraGain ="2,925" Camera amplification factor
DeadTime ="48800" />
<Shading Status ="0"
ShadingFactorX0 ="0.000000"
ShadingFactorX1 ="0.000000"
ShadingFactorX2 ="0.000000"
ShadingFactorX3 ="0.000000"
ShadingFactorX4 ="0.000000" />
<DefaultScale
x_nm ="26683" Default pixel size from construction
y_nm ="26710" Default pixel size from construction
StateX ="2" />
<CurrentScale
x_nm ="26741" Measured pixel size
y_nm ="26772" /> Measured pixel size
</Calibration>
<Statistics
NumberOfFlashes ="0"
NumberOfBootUps ="262" />

3 Camera Calibration in SW 605.xx Stations
3.4 XML Report (SW 605.xx)
Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020 63
Parameter name Value of camera Comment
<Diagnostics
StateOfGSM ="4"
LastError ="00" />
<HardwareState
ChecksumEEPROM ="OK"
Selftest ="OK" />
- <SensorSpecificData
PixelScale ="124">
<FieldOfView
StartX ="204"
StartY ="8"
SizeX ="1220" No. of pixels (image points) per line in field of
vision
SizeY ="1220" /> No. of pixels (image points) per column in field
of vision
<Extended
MaxIllum ="10"
MinSleep ="10"
ModusTrigger ="4"
ModusTransmit ="0"
ModusEnable ="2"
ModusSense ="12"
ModusExposure ="5"
Can0ToPlane ="1"
Can1ToPlane ="2"
Can2ToPlane ="4"
Can3ToPlane ="8"
Can4ToPlane ="16"
Can5ToPlane ="32"
FlashDelay ="0"
FinishDelay ="0"
ModusFlash ="0"
TriggerExposure ="20"
MaxExposure ="200" />
</SensorSpecificData>
</Sensorsystem>