5 Camera Calibration at the Vision Teach Station VTS 5.3 Calibration Sequence in the SIPLACE Vision Teach Station V5.1.1 SW Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS d…

5 Camera Calibration at the Vision Teach Station VTS
5.3 Calibration Sequence in the SIPLACE Vision Teach Station V5.1.1 SW
80 Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020
Fig.45: View before the brightness calibration
WARNING
Positioning the calibration tool
Observe the notice above the "Start FCCS" button before clicking on the button!
CAUTION
The brightness calibration tool has to be correctly placed in front of the camera in or-
der to calibrate the camera brightness.
► Put the correspondent white standard on the appropriate adapter and put the adapter
on the positioning table of the VTS.
► Now, move the adapter with the white standard towards the camera by using the avail-
able positioning options of the positioning table.
NOTICE
Leading up the white standard
► Lead up the adapter with the white standard as close as possible towards the camera
so that no external light can enter the camera.
The image shows live pictures of the camera.
Thus, you can check that the calibration tool is correctly positioned.
The results of the last successful calibration are read from the EEPROM of the camera and dis-
played in a list. Similar as on the 70X Station GUI, the calibration factors for each camera illumina-
tion level and the camera amplification factor are displayed.
●
You start the calibration with the "Start FCCS" button. The number of read-in images is coun-
ted in a progress bar during the calibration.

5 Camera Calibration at the Vision Teach Station VTS
5.3 Calibration Sequence in the SIPLACE Vision Teach Station V5.1.1 SW
Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020 81
Fig.46: View during the calibration
Fig.47: View after successful calibration
After a successful calibration, the new calibration factors and the differences since the last suc-
cessful calibration are displayed (as on the 70X Station GUI).
Click on the "Save" button to save the new calibration factors in the camera EEPROM. After sav-
ing, the wizard switches automatically to the next wizard view.
If the calibration fails, a corresponding error message is displayed below the image and in the res-
ult list. The values cannot be saved.

5 Camera Calibration at the Vision Teach Station VTS
5.4 Creating a Report
82 Operating Manual / Bedienungsanleitung Camera Calibration FCCS digital Kamerakalibrierung FCCS digital 04/2020
Fig.48: View after an incorrect calibration
5.4 Creating a Report
In the last view of the wizard, an HTML report of the calibration can be saved. The HTML report
corresponds in form and content to the PDF report that can be created on the 70X Station GUI
after a successful FCCS calibration.
After creation, the HTML report can be saved in the file system in a "Save as" dialog.
Fig.49: View to generate an HTML report