00198150-02_SM_TX_en - 第100页

6 Gantries 6.3 Trailing Cable and Printed Circuit Boards 100 Service Manual SIPLACE TX Series 06/2017 Removal ► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized reactivati…

100%1 / 316
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
Service Manual SIPLACE TX Series 06/2017 99
6.3.4 Replacing the Gantry Interface
Parts, Equipment and Tools
Gantry interface 1 [03116149‑xx]
Gantry interface 2 [03116147‑xx]
Overview
Fig.112: Gantry interface
1. Gantry interface
2. Trailing cable holder on gantry
Fig.113: Gantry interface
Gantry interface [03116149-xx]
1. Six fastening screws
 NOTICE!
Inversely Layout
The layout of the two gantry interfaces is the
same, but inversely.
.
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
100 Service Manual SIPLACE TX Series 06/2017
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
For a better access to the gantry interface you may remove the upper cover:
Fig.114: Removing the upper cover
Remove the four nuts at(2) and the four nuts
at(3) on location1. Repeat for location2.
Ask for the help of a second person for the next step.
Lift up the cover(1).
Unplug all electrical connections to the gantry interface. You may want to mark the positions
of these connections to make clear assignment easier later on.
Remove the six screws fastening the gantry interface and remove the gantry interface from
the machine.
Installation
Follow the removal instructions in reverse order for installation.
6 Gantries
6.3 Trailing Cable and Printed Circuit Boards
Service Manual SIPLACE TX Series 06/2017 101
6.3.4.1 Gantry Interface 1/2
Fig.115: Gantry interface [03116147-xx] – Gantry 1
Fig.116: Gantry interface [03116149-xx] – Gantry 2
Connectors [03116147-xx] [03116149-xx]
Connector Description
X1/X2 Power Y motor flat ribbon cable
X3 Power X motor flat ribbon cable
X4/X8 150V / 40V
X5/X9 Power fail, FDB Bus MCAN,X temperature sensor
X6/X10 GigE
X7 Power X motor track signals X axis
X11 Track signals Y axis
X12 Power Y motor
X13 Temperature sensor