00198150-02_SM_TX_en - 第197页

8 Placement Heads and Stationary Cameras 8.1 Fast Head Exchange Service Manual SIPLACE TX Series 06/2017 197 8 Placement Heads and Stationary Cameras DANGER Observe User Manual ► Please observe the safety instructions in…

100%1 / 316
7 Conveyor
7.12 Vacuum Tooling
196 Service Manual SIPLACE TX Series 06/2017
7.12 Vacuum Tooling
Spare parts
The following parts can be replaced for vacuum tooling:
Basic pack vacuum tooling TX [00588121‑xx]
Vacuum suction nozzle, nominal width 2 mm [03136878‑xx]
Maintenance unit vacuum tooling TX [03136432‑xx]
Valve unit assembly [03138689‑xx]
Cable: vacuum tooling [03139108‑xx]
Cable: vacuum tooling sensor [03139109‑xx]
Vacuum switch VSI V D M8-4 [03118829‑xx]
Cable: PCB sensor vacuum tooling 1 [03149630‑xx]
Cable: PCB sensor vacuum tooling 2 [03149631‑xx]
Equipment and tools
Assembly instructions "Basic pack vacuum tooling SIPLACE TX‑Series" [DE
+EN:00198328‑xx]
Removal / Installation
For more information about replacing spare parts, please read the assembly instructions.
8 Placement Heads and Stationary Cameras
8.1 Fast Head Exchange
Service Manual SIPLACE TX Series 06/2017 197
8 Placement Heads and Stationary Cameras
DANGER
Observe User Manual
Please observe the safety instructions in the user manual for all work!
8.1 Fast Head Exchange
By means of the Fast Head Exchange (FHE) it is possible to replace a placement head within 15
minutes.
NOTICE
CPP/M and C&P20P/M/M2 only
FHE is only possible with CPP and C&P20P/M/M2 heads only. TwinHeads must be calib-
rated manually.
See also
2 Replacing the SIPLACE C&P20 P/M2 Head [}202]
2 Replacing the SIPLACE CPP/M Head [}206]
8.1.1 Preparing the FHE in the Software
Fig.264: Select operator level
Click the
button to enter the Settings
menu.
Click the
button to open the Check and set
user settings menu.
Switch to operator level Machine service or bet-
ter.
Fig.265: Service menu
Click on Service
button.
Click the Fast hardware exchange button.
8 Placement Heads and Stationary Cameras
8.1 Fast Head Exchange
198 Service Manual SIPLACE TX Series 06/2017
Fig.266: Fast head exchange
Highlight the heads to be replaced.
Click on Prepare for exchange and shut down.
The following actions will be carried out automatically:
The current nozzles will be returned and calibra-
tion nozzles will be picked up, if present.
A nozzle and height reference run will be carried
out.
The machine will be shut down.
In a next step you can dismantle the heads.
8.1.2 Removing and Installing the Placement Head
For actually removing and installing the placement head hardware, proceed as described in
the relevant chapter.
Replacing the SIPLACE C&P20 P/M2 Head [}202]
Replacing the SIPLACE CPP/M Head [}206]
See also
2 Replacing the SIPLACE C&P20 P/M2 Head [}202]
2 Replacing the SIPLACE CPP/M Head [}206]