00198150-02_SM_TX_en - 第202页

8 Placement Heads and Stationary Cameras 8.2 Replacing the SIPLACE C&P20 P/M2 Head 202 Service Manual SIPLACE TX Series 06/2017 8.2 Replacing the SIPLACE C&P20 P/M2 Head NOTICE Vacuum test ► If required, perform …

100%1 / 316
8 Placement Heads and Stationary Cameras
8.1 Fast Head Exchange
Service Manual SIPLACE TX Series 06/2017 201
Fig.272: Performing calibration
Wait until calibration has been completed.
Fig.273: Finishing calibration
If there is an empty magazine in the machine
after the calibration has been completed, select
the Remove calibration nozzlesbutton.
Click on Finish.
If there are any problems during the reference
run (vacuum check), perform zero correction for
the pressure control valve.
The Fast Head Exchange has now been completed
and production can be restarted.
8 Placement Heads and Stationary Cameras
8.2 Replacing the SIPLACE C&P20 P/M2 Head
202 Service Manual SIPLACE TX Series 06/2017
8.2 Replacing the SIPLACE C&P20 P/M2 Head
NOTICE
Vacuum test
If required, perform a vacuum test before removing the placement head.
Read the "Service manual Vacuum test at C&P placement head" [DE+EN:
00196101‑xx] for this.
NOTICE
Fast Head Exchange (FHE)
Observe the instructions in section 8.1 "Fast Head Exchange" [}197] when exchan-
ging a head.
Parts, equipment and tools
C&P20 P placement head [03091157-xx] (without camera)
C&P20 M2 placement head [03125907Sxx] (without camera)
NOTICE
Vacuum pump/compressed air operation
As a spare part, the head is prepared for vacuum pump operation.
Convert the placement head for compressed air operation using the "Hold-circuit com-
plete/C&P20" [03005123Sxx] kit.
Torx screwdriver ESD 1.0-5.0 Nm [03078400-xx]
Bit holder for TorqueVario screwdriver [03078706-xx]
Extension/straight TX20 [03073256-xx]
Fig.274: Component sensor protective cap
[03092400‑xx]
Component sensor protective cap
[03092400‑xx]
Calibration tool version SST23 [03034148-
xx]
For additional work to the placement head:
Head mount [03056231‑xx]
Service manual "SIPLACE C&P20P head" [DE:00197489‑xx] [EN:00197490‑xx]
8 Placement Heads and Stationary Cameras
8.2 Replacing the SIPLACE C&P20 P/M2 Head
Service Manual SIPLACE TX Series 06/2017 203
Overview
Fig.275: C&P20P
1. Holding circuit connection
2. Intermediate distributor board (behind the cover)
3. Component sensor
Fig.276: Fastening screws
1. Four fastening screws (yellow marks)
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
CAUTION
Take great care when dismantling the placement head!
The component sensor prisms, underneath the placement head, could be damaged.
Never place the placement head down on the component sensor.
Fit the protective cap onto the component sensor for the placement head.