8 Placement Heads and Stationary Cameras 8.7 Calibration 224 Service Manual SIPLACE TX Series 06/2017 8.7.2 Calibration Procedure Fig.305: C&P calibration procedure

100%1 / 316
8 Placement Heads and Stationary Cameras
8.7 Calibration
Service Manual SIPLACE TX Series 06/2017 223
8.7.1 Calibrating the Heads and Cameras (SW70x)
Fig.302: Select operator level
Click the
button to enter the Settings
menu.
Click the
button to open the Check and set
user settings menu.
Switch to operator level Machine service or bet-
ter.
Fig.303: Service Menu
Click the
button to enter the Service menu.
Click the Automatic calibration button.
Fig.304: Automatic Calibration
Select Heads and cameras.
Click on the Continue button.
Follow the instructions on the next pages:
On the next page, select the gantries on which
the heads to be calibrated are located and then
click on the Next button.
The next step is to check the calibration condi-
tions (nozzle, calibration tool etc.). Follow the in-
structions provided.
After this step, calibration will begin. All required inter-
mediate steps (head height etc.) will be performed
automatically.
8 Placement Heads and Stationary Cameras
8.7 Calibration
224 Service Manual SIPLACE TX Series 06/2017
8.7.2 Calibration Procedure
Fig.305: C&P calibration procedure
9 Nozzle Changers and Nozzle Stations
9.1 Nozzle Changers and Nozzle Stations - Overview
Service Manual SIPLACE TX Series 06/2017 225
9 Nozzle Changers and Nozzle Stations
DANGER
Observe User Manual
Please observe the safety instructions in the user manual for all work!
9.1 Nozzle Changers and Nozzle Stations - Overview
Nozzle changer short [03103649‑xx]
1. Nozzle changer TwinStar (Short) [03062452-xx]
with eight magazines for 2 nozzles(3)
2. Magazine for 1 nozzle [03001807-xx]
3. Magazine for 2 nozzles [03005191-xx]
Magazine 20xx [03066107-xx]