00198150-02_SM_TX_en - 第226页

9 Nozzle Changers and Nozzle Stations 9.1 Nozzle Changers and Nozzle Stations - Overview 226 Service Manual SIPLACE TX Series 06/2017 Magazine 28xx [03065782-xx] Magazine 40xx [03101503-xx] 1. Nozzle station with reject …

100%1 / 316
9 Nozzle Changers and Nozzle Stations
9.1 Nozzle Changers and Nozzle Stations - Overview
Service Manual SIPLACE TX Series 06/2017 225
9 Nozzle Changers and Nozzle Stations
DANGER
Observe User Manual
Please observe the safety instructions in the user manual for all work!
9.1 Nozzle Changers and Nozzle Stations - Overview
Nozzle changer short [03103649‑xx]
1. Nozzle changer TwinStar (Short) [03062452-xx]
with eight magazines for 2 nozzles(3)
2. Magazine for 1 nozzle [03001807-xx]
3. Magazine for 2 nozzles [03005191-xx]
Magazine 20xx [03066107-xx]
9 Nozzle Changers and Nozzle Stations
9.1 Nozzle Changers and Nozzle Stations - Overview
226 Service Manual SIPLACE TX Series 06/2017
Magazine 28xx [03065782-xx]
Magazine 40xx [03101503-xx]
1. Nozzle station with reject bin for Twin/CPP head
2. Nozzle station with reject bin for C&P20P head
9 Nozzle Changers and Nozzle Stations
9.2 Replacing the Nozzle Changer
Service Manual SIPLACE TX Series 06/2017 227
9.2 Replacing the Nozzle Changer
Parts, Equipment and Tools
NC basic structure CPx/all assembly short [03103649-xx]
If required, NC adjusting plates [03021079-xx]
Depth measuring gauge (300mm) [03079617-xx]
Overview
Fig.306: Nozzle changer with four 4xxx magazines
1. Four nozzle magazines
2. Four fastening screws
3. Four levers for removal of nozzle magazines
4. Cover on the underside
The electronic and pneumatic components are
under the cover.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove all magazines.
Remove the four fastening screws.
Unplug the nozzles changer from all electrical and pneumatic connections.
Take care not to lose the support plates.
Carefully lift the nozzle changer out of the machine.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
Set the switch on the nozzle changer to 2-3 (valid for all SIPLACE TX machines).
Check the mechanical installation height of the nozzle changer (see 9.2.1 "Setting the
Nozzle Changer Height" [}228]).