9 Nozzle Changers and Nozzle Stations 9.3 Replacing Nozzle Station [03090348-xx] 230 Service Manual SIPLACE TX Series 06/2017 Installation ► Follow the removal instructions in reverse order for installation. Also observe…

100%1 / 316
9 Nozzle Changers and Nozzle Stations
9.3 Replacing Nozzle Station [03090348-xx]
Service Manual SIPLACE TX Series 06/2017 229
CAUTION
Crash hazard!
Do not place too many adjusting plates underneath.
► Calibrate the position of the nozzle changer.
9.3 Replacing Nozzle Station [03090348-xx]
Parts, equipment and tools
●
Nozzle station CPx complete / X4iS, XS [03090348-xx]
●
Measuring scale
●
Adjusting plates: support for nozzle reject device [03039514-xx]
Overview
Fig.308: Nozzle station
1. Nozzle station
2. Screws fastening the nozzle station
3. Hose
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
► Remove the two screws(2) fastening the nozzle station(1).
► Unplug the hose(3) for nozzle cleaning.
► Remove the nozzle station.
9 Nozzle Changers and Nozzle Stations
9.3 Replacing Nozzle Station [03090348-xx]
230 Service Manual SIPLACE TX Series 06/2017
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
► Check the height of the nozzle station (see below).
Fig.309: Setting the height of the nozzle station
(taking the standard nozzle station as example)
► The distance(1) between the contact surface of
the nozzle station and the top edge of the upper
guide rail of the gantry needs to be
266.0+0.1/-0.3mm. You may need to use shim
plates to adjust this.
 NOTICE!
Alternatively, you can measure from the top
edge of the lower guide rail of the gantry. In this
case the distance is 105.0+0.1/-0.3mm.
.
9 Nozzle Changers and Nozzle Stations
9.4 Replacing the Control Board Cable NC Valve [00334212-xx]
Service Manual SIPLACE TX Series 06/2017 231
9.4 Replacing the Control Board Cable NC Valve
[00334212-xx]
Parts, equipment and tools
●
Control board cable for NC valve [00334212-xx]
Overview
Fig.310: Control board cable
1. Nozzle changer
2. Control board cable for NC valve
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
► Remove the nozzle changer from the machine (see 9.2 "Replacing the Nozzle
Changer" [}227]).
► Unplug the connectors on the cable at both ends and remove the cable. You may also need to
remove cable ties.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
► Replace any opened cable ties.