00198150-02_SM_TX_en - 第240页
10 COT Insert 10.4 Replacing the 40-Fold Feeder Unlocking Device [03011582-xx] 240 Service Manual SIPLACE TX Series 06/2017 Fig.326: Feeder unlocking device 1. Two fastening screws 2. Complete feeder unlocking device 3.…

10 COT Insert
10.4 Replacing the 40-Fold Feeder Unlocking Device [03011582-xx]
Service Manual SIPLACE TX Series 06/2017 239
Installing the lifting mechanics
Fig.324: Installing the lifting mechanics
► Mount the interlock safety switch to the right lift-
ing mechanics.
► Place both lifting mechanics (left and right) in
position and fix them with two screws(1) each.
► Move both lifting mechanics to the outer posi-
tion(2) push them towards the inner side(3) and
tighten the screws(1).
► Reconnect the lifting mechanics to the pneumatic cylinders.
► Insert the locking flap bolt and place the washers in the correct position! Start at the inner side
at the COTi.
► Close the locking flap to fix the connection between the lifting mechanics and pneumatic cylin-
der.
► Perform necessary calibrations for the location.
See also
2 Replacing the Feeder Control Unit (FCU) [}241]
2 Replacing the Cutter on the COT Insert [03066690-xx] [}252]
10.4 Replacing the 40-Fold Feeder Unlocking Device
[03011582-xx]
Parts, equipment and tools
●
Feeder unlocking device 40-fold [03011582-xx]
Overview
Fig.325: Feeder unlocking device on COTi
1. Feeder unlocking device (under the FCU)
2. Feeder control unit (FCU)
3. Fastening screws (SW10)
The feeder unlocking device is installed at the loca-
tions in the COTi.

10 COT Insert
10.4 Replacing the 40-Fold Feeder Unlocking Device [03011582-xx]
240 Service Manual SIPLACE TX Series 06/2017
Fig.326: Feeder unlocking device
1. Two fastening screws
2. Complete feeder unlocking device
3. Connector for flat ribbon cable
4. Pneumatic connection
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
► Unplug the flat ribbon cable from the connector.
► Remove the two fastening screws.
► Pull the flat ribbon cable out of the side of the connector. You may have to lift the feeder un-
locking device slightly to do this.
Fig.327: Pneumatic connection
► Lift the feeder unlocking device up and off and
pull the pneumatic connection(1)off.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
► Reconnect the system to the electrical and compressed air systems.
NOTICE
Pneumatic connection
You might find it advisable to remove the cover on the back of the COTi. This gives the
compressed air hose more room to be moved. In certain circumstances, the COT insert
may need to be loosened and pulled out slightly to the front.
► Carefully press the feeder unlocking device towards the back and insert the fastening screws.
CAUTION
Do not pinch the cable.
► Make sure not to pinch or damage the cables running at the back (connected to the
FCU).

10 COT Insert
10.5 Replacing the Feeder Control Unit (FCU)
Service Manual SIPLACE TX Series 06/2017 241
10.5 Replacing the Feeder Control Unit (FCU)
Parts, Equipment and Tools
●
X-FCU V2, TX-/X-Series [03096377-xx]
Overview
Fig.328: FCU on COTi
1. Feeder control unit
The feeder control unit is installed at the locations in
the COTi.
3
3
1
3
2
Fig.329: FCU Overview
1. Complete FCU
2. Terminal strip
3. Fixing screws of the FCU
Depending on the version, there will be four or six
screws.