11 Cutter 11.5 Replacing the Baffle Plate [03019896-xx] Service Manual SIPLACE TX Series 06/2017 257 11.5 Replacing the Baffle Plate [03019896-xx] Parts, equipment and tools ● Baffle plate [03019896-xx] Overview Fig.355…

100%1 / 316
11 Cutter
11.4 Replacing the Metal Buffer/Spacer Distance Piece
256 Service Manual SIPLACE TX Series 06/2017
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
Fig.354: Removing metal buffer
Remove the plastic cover(1).
Take out the screws(2).
Remove the complete mounting strip(3).
Remove the metal buffer.
Installation
Follow the removal instructions in reverse order for further installation.
See also
2 Replacing the Cutter on the COT Insert [03066690-xx] [}252]
11 Cutter
11.5 Replacing the Baffle Plate [03019896-xx]
Service Manual SIPLACE TX Series 06/2017 257
11.5 Replacing the Baffle Plate [03019896-xx]
Parts, equipment and tools
Baffle plate [03019896-xx]
Overview
Fig.355: Cutter
1. Baffle plate [03019896-xx]
2. Two fastening screws
3. Clip, connecting baffle plate and protective guard
 CAUTION!
Risk of injury
There is a risk of injuring yourself on the cutting
edge of the blades.
.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
Straighten the two clips with pliers.
Remove the two screws fastening the baffle plate.
Remove the baffle plate unit from the cutter.
Installation
Follow the removal instructions in reverse order for installation.
See also
2 Replacing the Cutter on the COT Insert [03066690-xx] [}252]
11 Cutter
11.6 Replacing the Protective Guard [03019894-xx]
258 Service Manual SIPLACE TX Series 06/2017
11.6 Replacing the Protective Guard [03019894-xx]
Parts, equipment and tools
Protective guard [03019894-xx]
Overview
Fig.356: Protective guard on cutter
1. Protective guard [03019894-xx]
2. Five fastening screws
3. Clip connecting baffle plate and protective guard
 CAUTION!
There is a risk of injuring yourself on the cutting
edge of the blades.
.
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
Remove the five screws fastening the protective guard.
Straighten the two clips with pliers.
Remove the protective guard from the cutter.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
Fig.357: Fitting the protective guard
Make sure that the five fastening screws are
completely countersunk. The screws must be
flush with the protective guard.
Ensure that there is a gap between the cutter
blade and the edge of the baffle plate inside(1).
If everything is correct, there should be a contact
at position(2).
See also