00198150-02_SM_TX_en - 第257页
11 Cutter 11.5 Replacing the Baffle Plate [03019896-xx] Service Manual SIPLACE TX Series 06/2017 257 11.5 Replacing the Baffle Plate [03019896-xx] Parts, equipment and tools ● Baffle plate [03019896-xx] Overview Fig.355…

11 Cutter
11.4 Replacing the Metal Buffer/Spacer Distance Piece
256 Service Manual SIPLACE TX Series 06/2017
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
► Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
Fig.354: Removing metal buffer
► Remove the plastic cover(1).
► Take out the screws(2).
► Remove the complete mounting strip(3).
► Remove the metal buffer.
Installation
► Follow the removal instructions in reverse order for further installation.
See also
2 Replacing the Cutter on the COT Insert [03066690-xx] [}252]

11 Cutter
11.5 Replacing the Baffle Plate [03019896-xx]
Service Manual SIPLACE TX Series 06/2017 257
11.5 Replacing the Baffle Plate [03019896-xx]
Parts, equipment and tools
●
Baffle plate [03019896-xx]
Overview
Fig.355: Cutter
1. Baffle plate [03019896-xx]
2. Two fastening screws
3. Clip, connecting baffle plate and protective guard
CAUTION!
Risk of injury
There is a risk of injuring yourself on the cutting
edge of the blades.
.
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
► Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
► Straighten the two clips with pliers.
► Remove the two screws fastening the baffle plate.
► Remove the baffle plate unit from the cutter.
Installation
► Follow the removal instructions in reverse order for installation.
See also
2 Replacing the Cutter on the COT Insert [03066690-xx] [}252]

11 Cutter
11.6 Replacing the Protective Guard [03019894-xx]
258 Service Manual SIPLACE TX Series 06/2017
11.6 Replacing the Protective Guard [03019894-xx]
Parts, equipment and tools
●
Protective guard [03019894-xx]
Overview
Fig.356: Protective guard on cutter
1. Protective guard [03019894-xx]
2. Five fastening screws
3. Clip connecting baffle plate and protective guard
CAUTION!
There is a risk of injuring yourself on the cutting
edge of the blades.
.
Removal
► Switch off the machine, disconnect it from the power supply and secure it to prevent
unauthorized reactivation. Observe the instructions in section 1.2 "Preparatory Work..." [}15].
► Remove the cutter from the machine.
Replacing the Cutter on the COT Insert [03066690-xx] [}252]
► Remove the five screws fastening the protective guard.
► Straighten the two clips with pliers.
► Remove the protective guard from the cutter.
Installation
► Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
Fig.357: Fitting the protective guard
► Make sure that the five fastening screws are
completely countersunk. The screws must be
flush with the protective guard.
► Ensure that there is a gap between the cutter
blade and the edge of the baffle plate inside(1).
► If everything is correct, there should be a contact
at position(2).
See also