00198150-02_SM_TX_en - 第292页

13 Docking Station for Component Trolley 13.6 Replacing the Positions End Switch of the Component Trolley Locking Device [03033395-xx] 292 Service Manual SIPLACE TX Series 06/2017 13.6 Replacing the Positions End Switch …

100%1 / 316
13 Docking Station for Component Trolley
13.5 Replacing the Locking Lever [03025104-XX]
Service Manual SIPLACE TX Series 06/2017 291
13.5 Replacing the Locking Lever [03025104-XX]
Parts, equipment and tools
Horizontal tensioner DE-STA-CO 225-U [03025104-xx]
Overview
1
2
Fig.412: Locking lever left and right
1. Locking lever – on the left side
2. Locking lever – on the right side
Removal
4
3
2
1
Fig.413: Removing the locking lever
1. Locking lever
2. Four fastening screws
3. Position end switch
4. Limit switch
Remove the four screws(2) (twoeach at the top
and bottom) fastening the locking lever(1).
Remove the locking lever.
Installation
Loosely screw in the new locking lever.
Align the locking lever to the edge (3) and tighten the four fastening screws.
Check that the limit switch (4) is actuated when the locking lever is closed. Correct the posi-
tion of the locking lever if necessary.
Check the position end switch function, by trying out the locking procedure.
13 Docking Station for Component Trolley
13.6 Replacing the Positions End Switch of the Component Trolley Locking Device [03033395-xx]
292 Service Manual SIPLACE TX Series 06/2017
13.6 Replacing the Positions End Switch of the Component
Trolley Locking Device [03033395-xx]
Parts, equipment and tools
Position end switch [03033395-xx]
Overview
1
2
Fig.414: Position end switch left and right
1. Position end switch – on the left side
2. Position end switch – on the right side
Removal
Fig.415: Removing the position end switch
1. Position end switch with connection cable
2. Two fastening screws
3. Connection cable to connector unit
4. Actuation by locking lever
 DANGER!
Switch off the voltage supply
Press the ON/OFF button to switch off and then
unplug the power supply.
.
Remove the two screws fastening the limit switch.
Open the casing of the connector at the back and label the terminal connections.
NOTICE
Connector for left and right position end switch
The connection cables for the left and right position end switch are connected to a
common connector.
Disconnect the connection cable for the relevant position end switch, in the connector.
Unthread the connection cable and remove the position end switch.
13 Docking Station for Component Trolley
13.7 Replacing the 40-Fold Feeder Unlock Device [03011582-xx]
Service Manual SIPLACE TX Series 06/2017 293
Installation
Loosely screw in the new position end switch.
Run the connection cable to the connector.
Reconnect the connection cable and close the connector casing.
Align the position end switch so that the locking lever actuator switches properly.
Tighten the fastening screws.
Connect the power pack connection cable and press the ON/OFF button to switch on.
Check the position end switch function by trying out the locking procedure.
13.7 Replacing the 40-Fold Feeder Unlock Device
[03011582-xx]
Parts, equipment and tools
40 fold feeder unlocking device [03011582-xx]
Overview
1
Fig.416: Feeder unlocking device on docking station
1. 40 fold feeder unlocking device
Removal / installation
The 40-fold feeder unlocking device is the same assembly used in the COTi. The service work is
identical with the procedure used for the COTi. All necessary service work is described there.