00198150-02_SM_TX_en.pdf - 第297页

13 Docking Station for Component Trolley 13.11 Replacing the Control Valve [03003489-xx] Service Manual SIPLACE TX Series 06/2017 297 13.11 Replacing the Control Valve [03003489-xx] Parts, equipment and tools ● Control v…

100%1 / 316
13 Docking Station for Component Trolley
13.10 Replacing the Unlocking Pushbutton [00334095-xx]
296 Service Manual SIPLACE TX Series 06/2017
13.10 Replacing the Unlocking Pushbutton [00334095-xx]
Parts, equipment and tools
●
Unlocking pushbutton [00334095-xx]
Overview
1
Fig.420: Unlocking pushbutton on docking station
1. Unlocking pushbutton
Removal / installation
4
6
5
1
3
2
Fig.421: Removing the unlocking pushbutton
1. ON / OFF switch
2. Power supply plug
3. Cover
4. Bar for clamping the cover
5. Four screws fastening the cover
6. Terminal block for pushbutton
 DANGER!
Switch off the voltage supply
Press the ON/OFF button (1) to switch off and
then unplug the power supply (2).
.
► Remove the four screws (5) fastening the cover (3). The cover is clamped in place with the
help of the bar (4).
► Pull the cover (1) out of the docking station.
► Take care not to damage the earth connection.
► Remove the screw fastening the terminal block (6) of the pushbutton.
► Turn the terminal block and extract it from its fixtures.
► Label the connection leads and disconnect these from the terminal block.
► Connect the connection cables to the new pushbutton.
► Fit the new pushbutton.
► Refit the cover.
► Connect the power pack connection cable and press the ON/OFF button to switch on.
► Check the function of the pushbutton by trying out the unlocking procedure.
13 Docking Station for Component Trolley
13.11 Replacing the Control Valve [03003489-xx]
Service Manual SIPLACE TX Series 06/2017 297
13.11 Replacing the Control Valve [03003489-xx]
Parts, equipment and tools
●
Control valve [03003489-xx]
Removal / installation
1
Fig.422: Removing the control valve
 DANGER!
Switch off the voltage supply
Press the ON/OFF button to switch off and then
unplug the power supply.
Switch off the compressed air supply.
.
► Disconnect the electrical and pneumatic connec-
tions to the control valve(1).
► Remove the fastening screws and remove the
control valve.
► Install the new control valve.
► Reconnect to the electrical and compressed air
systems.
13 Docking Station for Component Trolley
13.11 Replacing the Control Valve [03003489-xx]
298 Service Manual SIPLACE TX Series 06/2017