00198150-02_SM_TX_en - 第297页

13 Docking Station for Component Trolley 13.11 Replacing the Control Valve [03003489-xx] Service Manual SIPLACE TX Series 06/2017 297 13.11 Replacing the Control Valve [03003489-xx] Parts, equipment and tools ● Control v…

100%1 / 316
13 Docking Station for Component Trolley
13.10 Replacing the Unlocking Pushbutton [00334095-xx]
296 Service Manual SIPLACE TX Series 06/2017
13.10 Replacing the Unlocking Pushbutton [00334095-xx]
Parts, equipment and tools
Unlocking pushbutton [00334095-xx]
Overview
1
Fig.420: Unlocking pushbutton on docking station
1. Unlocking pushbutton
Removal / installation
4
6
5
1
3
2
Fig.421: Removing the unlocking pushbutton
1. ON / OFF switch
2. Power supply plug
3. Cover
4. Bar for clamping the cover
5. Four screws fastening the cover
6. Terminal block for pushbutton
 DANGER!
Switch off the voltage supply
Press the ON/OFF button (1) to switch off and
then unplug the power supply (2).
.
Remove the four screws (5) fastening the cover (3). The cover is clamped in place with the
help of the bar (4).
Pull the cover (1) out of the docking station.
Take care not to damage the earth connection.
Remove the screw fastening the terminal block (6) of the pushbutton.
Turn the terminal block and extract it from its fixtures.
Label the connection leads and disconnect these from the terminal block.
Connect the connection cables to the new pushbutton.
Fit the new pushbutton.
Refit the cover.
Connect the power pack connection cable and press the ON/OFF button to switch on.
Check the function of the pushbutton by trying out the unlocking procedure.
13 Docking Station for Component Trolley
13.11 Replacing the Control Valve [03003489-xx]
Service Manual SIPLACE TX Series 06/2017 297
13.11 Replacing the Control Valve [03003489-xx]
Parts, equipment and tools
Control valve [03003489-xx]
Removal / installation
1
Fig.422: Removing the control valve
 DANGER!
Switch off the voltage supply
Press the ON/OFF button to switch off and then
unplug the power supply.
Switch off the compressed air supply.
.
Disconnect the electrical and pneumatic connec-
tions to the control valve(1).
Remove the fastening screws and remove the
control valve.
Install the new control valve.
Reconnect to the electrical and compressed air
systems.
13 Docking Station for Component Trolley
13.11 Replacing the Control Valve [03003489-xx]
298 Service Manual SIPLACE TX Series 06/2017