3 SMPS 3.5 MGCUs Service Manual SIPLACE TX Series 06/2017 43 3.5 MGCUs 3.5.1 Overview of MGCUs SIPLACE TX1/TX2/TX2i Standard Fig.34: SIPLACE TX1/TX2/TX2i Standard

3 SMPS
3.4 Checking For Absence of Voltage
42 Service Manual SIPLACE TX Series 06/2017
Fig.32: Measuring voltage
DANGER
Measurement values below 5VDC
Measure between the following points:
► X303 (IN) – X305 (GND) < 5VDC
► X304 (OUT) – X305 (GND) < 5VDC
Fig.33: LED on the capacitor battery(CAP)
► Check the LED on the capacitor battery
(CAP).
DANGER!
Once the LED on the capacitor battery
(CAP) does not light any longer, it is pos-
sible to work on the power supply without
hazard!
.

3 SMPS
3.5 MGCUs
Service Manual SIPLACE TX Series 06/2017 43
3.5 MGCUs
3.5.1 Overview of MGCUs
SIPLACE TX1/TX2/TX2i Standard
Fig.34: SIPLACE TX1/TX2/TX2i Standard

3 SMPS
3.5 MGCUs
44 Service Manual SIPLACE TX Series 06/2017
SIPLACE TX2/TX2i micron
Fig.35: SIPLACE TX2/TX2i micron