Ceramic substrate centering SIPLACE S- 27 HM 2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM 12/2004 Edition 45 : Insert the p iece of ho se you r emoved o nce m ore, togeth er with th e non-r et…

100%1 / 66
2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM Ceramic substrate centering SIPLACE S-27 HM
12/2004 Edition
44
: Disconnect the compressed air line from the non-return valve and remove the valve.
2
: Disconnect the compressed air hose downstream of the elbow to allow you to fit the non-return
valve.
2
Non-return valve
Cut through the compressed
air hose
Ceramic substrate centering SIPLACE S-27 HM 2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM
12/2004 Edition
45
: Insert the piece of hose you removed once more, together with the non-return valve and
T-piece.
Shorten the hose accordingly.
2
Make sure that the non-return valve is installed in the correct position (see picture). 2
2
2
: Connect the compressed air hose to the ceramic substrate centering to the T-piece.
2
Non-return valve
T-piece
T-piece
PUN4 hose
to solenoid valve
2 Retrofit instructions: ceramic substrate centering for SIPLACE S-27 HM Ceramic substrate centering SIPLACE S-27 HM
12/2004 Edition
46
: Fit the solenoid valve using two screws (see photograph below).
: Connect the compressed air hose to the ceramic substrate centering to the solenoid valve.
2
2
2
2
2
2
2
2
2
T-piece
Connecting hose
PUN4 for T-piece
Solenoid valve
PUN4 compressed
air hose to ceramic
substrate centering