CP12 - 第6页
E-by SIPLACE CP12 & CP6 Move to Service Positi on and Shut Down Ma chine Part Exchange 2/2 CAUTION! Refer to safety inst ructions in user manual before working on the machine. ESD guidelines are to be followed Tool: …

E-by SIPLACE CP12 & CP6 Move to Service Position and Shut Down Machine
Part Exchange
1/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
1. Click on "stop production" icon. 2. Click on "check sensors and functions"
icon.
3. Click on "move gantry 1 to service position"
icon.
4. Press start button. 5. Click on "setting options conveyor interface
and shut down" icon.
6. Click on "shut down the machine" icon.

E-by SIPLACE CP12 & CP6 Move to Service Position and Shut Down Machine
Part Exchange
2/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
7. Switch off machine. 8. Open cover. 9. Carefully move gantry into working area.
Check for obstruction before move.

E-by SIPLACE CP12 & CP6 Removing the Turning Station
Part Exchange
1/1
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: PN 00341780- Turning System. DLM
1. Disconnect both cables 1 and 2. 2. Remove fixing screw with 3mm Allen key. 3. Carefully lever the turning station back-
wards, off the locating pins and gently pull it
out of the head.