CP12 - 第7页

E-by SIPLACE CP12 & CP6 Removing the Turning Station Part Exchange 1/1 CAUTION! Refer to safety inst ructions in user manual before working on the machine. ESD guidelines are to be followed Tool: PN 00341780- Turning…

100%1 / 12
E-by SIPLACE CP12 & CP6 Move to Service Position and Shut Down Machine
Part Exchange
2/2
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: Wear Part: Consumables:
7. Switch off machine. 8. Open cover. 9. Carefully move gantry into working area.
Check for obstruction before move.
E-by SIPLACE CP12 & CP6 Removing the Turning Station
Part Exchange
1/1
CAUTION! Refer to safety instructions in user manual before working on the machine.
ESD guidelines are to be followed
Tool: PN 00341780- Turning System. DLM
1. Disconnect both cables 1 and 2. 2. Remove fixing screw with 3mm Allen key. 3. Carefully lever the turning station back-
wards, off the locating pins and gently pull it
out of the head.