00197190-03_VD_SIPLACE_Pro_10_1_SP1_DE_EN - 第54页

SIPLAC E Pro V10. 1 SP1 / Softwar e Version Desc ripti on Ausgabe 02/2013 Edit ion 54 Body Offset Since SI PLACE Pr o 2.0, th e com ponent sha pe des cri ption no l onger has a bo dy offs et (x, y). W ith the bod y offs …

100%1 / 128
SIPLACE Pro V10.1 SP1 / Software Version Description Ausgabe 02/2013 Edition
53
6 Restrictions
In the following, existing restrictions in SIPLACE Pro are described.
Miscellaneous
A complete import of customer data from the line computer can sometimes be very time-
consuming, depending on the volume of data involved and the computing system used for the
process (may take up to several hours).
10-fold and 15-fold stick magazines can not be combined on the same line feeder.
When importing setup files (.rt files) from the line computer, you can not import more than one
tray per level. If you import more than one tray per level, you need to create them manually in
SIPLACE Pro.
SIPLACE Pro object names (e.g., recipe) must not exceed 125 ASCII characters (including
folder names). If the station software is 504 or older, these names are shortened to 20 ASCII
characters.
If various users optimize the same job at the same time, the job which was most recently
completed successfully will overwrite all corresponding recipes
The operator must manually place manual tray carriers (carrier 30, carrier 51, carrier X and
carrier SX) in the initial setup.
If you work with reduced acceleration for a component shape, this is seen as a "special case"
and the accuracy of 5% for the simulated Optimizer production time will not be achieved.
The Optimizer does not check if the tray size is bigger than the carrier.
The WPC can take up to 10 different component types per level. This restriction does not apply
for machines from station software version 70x.
Station-wise Download
When the line control server is rebooted, station-wise downloading will be canceled. After
rebooting, you will need to perform a complete line download to restart production.
Station-wise downloading supports setup changes in asynchronous dual operation only when
you have the same definition for both lanes.
Station-wise downloading supports synchronous dual operation as of station software version
704.
SIPLACE Pro V10.1 SP1 / Software Version Description Ausgabe 02/2013 Edition
54
Body Offset
Since SIPLACE Pro 2.0, the component shape description no longer has a body offset (x, y). With
the body offset in former versions you could move the basic body of the component shape.
The following restrictions should be considered:
Station software
>=
505
All databases from type SIPLACE Pro 1.4.x.x will be adjusted to SIPLACE Pro 3.0. The body
offset is automatically considered in the pickup position.
Station software
504
Stations with this software do not support any pickup positions. Setups with component shapes
that are described in SIPLACE Pro 1.4.x.x with a body offset have to be adapted manually after
an upgrade to SIPLACE Pro 3.0.
Changed Values of a Component Packaging
If you change the values for a type of component packaging after this has been assigned to a
component, these values will not be updated for the component concerned.
The component package has to be re-assigned to the component after the component package
values have been modified.
ASCII Centroid Import
If component shapes are selected in the ASCII Centroid Import Wizard, all the existing links
between components and component shapes will be overwritten with the imported information.
VHF P&P head
Supported on the SX1/SX2 V2 placement machine only.
WPC5 / WPC6
Components up to a height of 30mm can be placed with a force of 70N with the WPC5 as of
serial number 1485 and the WPC6 as of serial number C1486 only.
Due to the refill module, components > 25mm cannot be positioned on the levels 1 3 and
27 28 on the WPC6. The levels 4 28 will be set up automatically by the SIPLACE Pro
Optimizer. The levels 1 3 have to be blocked manually by the operator.
X4i S placement machine
The traveling range in X direction is limited for the gantries 2 and 4 on the X4i S placement
machine.
If a pin picker is installed on the X4i S placement machine, the maximum board length is
410mm.
X3 S and X4 S placement machines
If a pin picker is installed on the X3 S and X4 S placement machines, the maximum board length is
410mm.
SIPLACE Pro V10.1 SP1 / Software Version Description Ausgabe 02/2013 Edition
55
TrayStak Feeder AX
The feeder is only supported on the X4i S placement machine and can be positioned on the
locations 2 and 3 only.
A table of type "DX Table 40 X" has to be configured. Additionally, the "WPC X" table insert has
to be selected s in order to release the traveling range of the placement head for the feeder.
Only one Dip module LDU-X can be installed beside the feeder.
If 2 TrayStak Feeder AX are installed together with an LDU-X, the table has to be manually
selected in the Auto Configuration of the station software.
No nozzle changer support.
Stationary camera cannot be used.
CPP placement head supported only.
Feeder and placement heads are neither controlled in SIPLACE Pro nor in the station software.
Due to the hardware, the sequence oft he components (chain) cannot be warranted. Therefore,
setup verification with SIPLACE Setup Center cannot be performed.
After the machine has been rebooted or the feeder has been locked / unlocked, the feeder has
to be manually activated with the buttons on the feeder each time.
If the feeder is used without a reject conveyor, this may result in incomplete head cycles what
causes a reduced placement performance.
If there is no space to put back the component, it will be rejected.