User Manual E-by-SIPLACE 用户手册 - 第125页
User manual E by SIPLACE 3 Technical data and assemblies From software version SC 712.1 Edition 05/2019 3.5 Placement hea d 125 3.5.3 SIPLACE CP6 for h igh-speed IC placement Item no. 03105986-xx SIPLACE CP6 Item no. 031…

3 Technical data and assemblies User manual E by SIPLACE
3.5 Placement head From software version SC 712.1 Edition 05/2019
124
3.5.2.3 Technical data
3
3.5.2.4 Operation with a vacuum pump
The SIPLACE CP12 uses a vacuum pump for more efficient vacuum generation (see Section
3.5.4
, page 129).
SIPLACE CP12
with component camera type 30 GigE
Range of components
*a
01005 to flip-chip, bare die, PLCC44, BGA, µBGA, TSOP, QFP, SO to
SO32, DRAM
Component specification
Max. height
Max. height with PP head
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
*b
Max. weight
7.5 mm
*c
8.5 mm
*d
0.3 mm
0.15 mm
0.25 mm
0.14 mm
0.4 x 0.2 mm²
18.7 x 18.7 mm²
2 g
Nozzle types 30xx
X/Y accuracy
*e
± 41 μm/3σ
Angular accuracy ± 0.5°/3σ
Component range 98.5%
Illumination levels 5
Possible illumination level setting
256
5
*)a Please note that the component range that can be placed is also affected by the pad geometry, the customer-specific stan-
dards and the packaging tolerances.
*)b For high volume 01005-placement it is recommended to equip the CP12 with its optional 01005-package that contains spe-
cial nozzles and low force segments.
*)c With stand alone head configuration.
*)d 19 mm with PP head configuration and one nozzle is removed,
*)e The accuracy value was measured using the vendor-neutral IPC standard.

User manual E by SIPLACE 3 Technical data and assemblies
From software version SC 712.1 Edition 05/2019 3.5 Placement head
125
3.5.3 SIPLACE CP6 for high-speed IC placement
Item no. 03105986-xx SIPLACE CP6
Item no. 03101672-xx, Component camera, type 30 GigE
3
Fig. 3.5 - 5 SIPLACE CP6 - Function groups, part 1
(1) Vacuum generator
(2) Turning station, DP axis
(3) Star with 6 sleeves - star axis
(4) Forced air valve
(5) Silencer

3 Technical data and assemblies User manual E by SIPLACE
3.5 Placement head From software version SC 712.1 Edition 05/2019
126
3
Fig. 3.5 - 6 SIPLACE CP6 - Function groups, part 2
3
(1) Intermediate distributor board, beneath the cover
(2) Star drive - DR motor
(3) Z axis motor
(4) Valve adjustment drive
(5) Component camera, type 30 GigE