User Manual E-by-SIPLACE 用户手册 - 第203页

User manual E by SIPLACE 5 Working with the machine From software version SC 712.1 Edition 05/2019 5.2 Controls and displays 203 5.2 Controls and displays 5.2.1 Overview 5 Fig. 5.2 - 1 Controls and displays 5 (1) Main sw…

100%1 / 324
5 Working with the machine User manual E by SIPLACE
5.1 Staff profiles From software version SC 712.1 Edition 05/2019
202
5.1.3 Activity level "Machine service"
5.1.3.1 Tasks
Customers should be given the activity level Machine service to perform the following tasks:
Mounting replacement parts
Editing machine data
Changing machine options
Calibrating the machine
Test bench inspection
User manual E by SIPLACE 5 Working with the machine
From software version SC 712.1 Edition 05/2019 5.2 Controls and displays
203
5.2 Controls and displays
5.2.1 Overview
5
Fig. 5.2 - 1 Controls and displays
5
(1) Main switch (5) Stop button (black)
(2) Start button (white) (6) LCD touchscreen
(3) EMERGENCY STOP button (7) Indicator lamps with buzzer
(4) Keyboard (T) Direction of PCB transport
(1)
(4)
(3)
(2)
(6)
(7)
(5)
5 Working with the machine User manual E by SIPLACE
5.2 Controls and displays From software version SC 712.1 Edition 05/2019
204
5.2.2 Controls on the machine's operator panels
All the controls can be reached by a 1.40 m tall person. There is a monitor and a keyboard on both
sides of the machine.
The start and stop buttons are located near the keyboard. The on-screen dialog will occasionally
prompt you to activate certain actions using buttons, and this arrangement will make it easier for
you both to activate and to interactively control these actions.
Main switch 5
The main power switch is used to switch the power supply to the machine on and off.
5
Stop button (black) 5
This button is used to stop the machine.
Start button (white) 5
This button starts the machine after it has been switched on or after faults have been eliminated.
EMERGENCY STOP button 5
The EMERGENCY STOP button latches in the ON position when pressed. The power supply to
the gantry axes, the changeover tables, conveyors and used tape cutters is interrupted and the
voltage supplied to the star axes of the placement heads is reduced. Turn the button to release it.
LCD touchscreen 5
There is a flat LCD screen with a touch-sensitive surface (touchscreen) on either side of the place-
ment machine.
DANGER
Lethal voltages!
Some parts inside the machine carry potentially lethal voltages - even when switched off
at the main power switch.