User Manual E-by-SIPLACE 用户手册 - 第312页

6 Station extensions User manual E by SIPLACE 6.11 SIPLACE Component Reject Conveyor E From software version SC 712.1 Edition 05/2019 312 6.11.3 T echnical data – Dimension: – Width 80mm – Height 213. 7 mm (e xcluding kn…

100%1 / 324
User manual E by SIPLACE 6 Station extensions
From software version SC 712.1 Edition 05/2019 6.11 SIPLACE Component Reject Conveyor E
311
6.11.1 General
The SIPLACE Component Reject Conveyor E is designed so that defective components (verified
by placement machine vision system) are placed onto conveyor belt and transferred out of ma-
chine for operator retrieval. It is handled like any other feeder for E by SIPLACE and can be
mounted onto its feeder tables.The purposes of Component Reject Conveyor are:
Safely retrieve the reject component without opening / stopping machine.
Store the rejected component on the conveyor belt, so that is not damaged and can still be
reused.
The SIPLACE Component Reject Conveyor E will be used on the changeover table for E by
SIPLACE. The same locating pin as E-series feeder is used in the SIPLACE Component Reject
Conveyor E to position it in place. In addition, a clamping mechanism is designed to fix it onto the
changeover table for E by SIPLACE. The SIPLACE Component Reject Conveyor E occupies 7
omega rail tracks and it can be placed anywhere on the table.
6.11.2 Description
Electrical power is provided to the SIPLACE Component Reject Conveyor E via Pogo pin connec-
tion. The placement machine places a defective component on the front end of the SIPLACE
Component Reject Conveyor E conveyor belt (Component Present Sensor, item 2 in fig. 6.11 - 1)
between detecting sensor. Once the Component Present Sensor is triggered, the belt will index
the component one pitch distance from placement point according to the set pitch length. After the
first component has been placed and moved out, the next reject component can be placed at
placement point without risk of component stacking.
At any time, the operator can press the RUN / RESET button (item 5 in fig. 6.11 - 1) and the belt
will run, transporting the components on the belt toward the rear of the SIPLACE Component Re-
ject Conveyor E. The operator can then remove components from the rear belt at any time without
opening the machine cover. Without any intervention, the conveyor continues to index each time
a component is placed on the belt. The lead component will eventually approach the end of the
conveyor, and trigger the rear sensor. The rear sensor will trigger an audible alarm to sound for
operator intervention. The alerted operator then removes components from the belt.
Even after the buzzer sounded, the conveyor is still functions normally; continue to index each
time a component is placed on the belt. If the operator does not intervene and manually clear the
rejected component from belt, the lead component will eventually fall off the end of belt and caught
by container at the end of the SIPLACE Component Reject Conveyor E. There is no direct com-
munication between SIPLACE Component Reject Conveyor E and the placement machine. The
placement machine does not know if the belt / rear container is full with rejected components.
6 Station extensions User manual E by SIPLACE
6.11 SIPLACE Component Reject Conveyor E From software version SC 712.1 Edition 05/2019
312
6.11.3 Technical data
Dimension:
Width 80mm
Height 213.7 mm (excluding knurled knob, max height 17.5 mm at fully retracted)
Length 611 mm
Location on E by SIPLACE:
Occupies 7 omega rail tracks and can be placed anywhere on the table, both Location 1
and Location 2
Component sizes:
Maximum weight: 100 gr
Minimum Height: 1 mm
Minimum Size: 3 x 1.4 mm
Maximum Height: 19 mm
Maximum Size: 60 x 60 mm
Pitch Settings:
Component height 10 - 19 mm ' Set to pitch 0 ' Conveyor will index 268 mm
Component height less than 10 mm ' Set to pitch 1 - 9 ' Conveyor will index 10 - 100 mm,
to be selected depend on component's size.
Communication
Pogo-pin Interface
Weight
max 5.5 kg
User manual E by SIPLACE 6 Station extensions
From software version SC 712.1 Edition 05/2019 6.11 SIPLACE Component Reject Conveyor E
313
6.11.4 Safety Instructions
Please ensure that all safety instructions in this section have been followed.
6
CAUTION
Safety of Operators and Other Persons
Machine operators may only carry out work for which they have been adequately trained and
with which they are totally familiar!
NEVER open one of the protective covers if you are not totally familiar with the use and func-
tion of this machine!
The protective covers may only be opened during operation if you are requested to do so in
this Manual or by a dialog in the station software!
Never remove this module from the changeover table while the host machine is in operation.
Never make changes, however minor, unless you are totally aware of the effect they will
have on the overall functioning of the system.
This machine must always be set-up, retooled and maintained by appropriately trained per-
sonnel.
Only use original spare parts and authorized accessories of ASM Assembly Systems. The
use of other parts will affect safety and can invalidate the liability for any consequential dam-
age.
Do not make modifications to the safety equipment, in particular NEVER deactivate circuit-
breakers or remove safety devices.
For your own safety, wear work clothes that conform to the guidelines of the professional
association, i.e. no wide sleeves, etc.
Reduce the risks by not wearing scarves, chains or ties at your work post.
People with long hair must wear a protective head covering.
Always follow the safety regulations specific to your country!
WARNING
Voltage
This machine is electrically driven. When electrical devices are in use, certain parts carry a voltage of
25Vdc!
Before performing any work on parts which conduct electricity, switch the placement machine off
at the main switch and unplug the Harting connector to remove power to this module.
There is a risk of fatal injuries, severe injuries and/or considerable damage to equipment if any of
these instructions are not followed!