User Manual E-by-SIPLACE 用户手册 - 第318页
7 Maintenance User manual E by SIPLACE 7.2 Maintenance on Base Machine From software version SC 712.1 E dition 05/2019 318 7 7 7 7 a) This value is for 3 shift operation (7500 hours of operation ). Longer inter vals can …

User manual E by SIPLACE 7 Maintenance
From software version SC 712.1 Edition 05/2019 7.2 Maintenance on Base Machine
317
7.2 Maintenance on Base Machine
7
Base machine Every 6
months
Every 12
months
– Checking the Fans on the MGCU
X
– Checking the safety features on machines
X
– Checking and Cleaning/Replacing (if required) the Compressed Air Filter
X
– Cleaning/Replacing the Head Exhaust Air Filter
X
– Greasing and clean the X axis guide bearing
X
– Cleaning the Linear Guides of the X Axis
X
– Grease and clean the Y axis guide bearing
X
– Cleaning the Linear Guides of the Y Axis
X
– Cleaning the X Axis Scale
X
– Cleaning the Y Axis Scale
X
– Cleaning the Protective Covers
X
– Checking/Cleaning/Replacing the Gas Pressure Shock Absorbers on the
Protective Covers
X
– Replace the loose bearing lubrication system X axis and Y axis (if pres-
ent)
X
– Grease and clean the X and Y axis guide bearing
X

7 Maintenance User manual E by SIPLACE
7.2 Maintenance on Base Machine From software version SC 712.1 Edition 05/2019
318
7
7
7
7
a) This value is for 3 shift operation (7500 hours of operation). Longer intervals can be planned for other operation setups.
Conveyor Every 6
months
Every 12
months
– Cleaning and Preserving the Conveyor
– Hexagonal shafts
– Linear guide rails
– Ball screws
– Guide shaft
X
Component Docking Unit Every 6
months
Every 12
months
– Function Test of Tape Cutter
X
– Greasing the Tape Cutter
X
– Greasing the Cutting Blade
X
– Greasing the COT Insert
X
– Greasing the Locator Bearing on the Component Trolley for SIPLACE
SmartFeeder E
X
Optical Systems Every 6
months
Every 12
months
– Cleaning the IC and FC Cameras
X
– Cleaning the PCB Barcode Scanner (if availible)
X
Cleaning and Checking tasks
Vacuum pump
Every 6
months
Every 12
months
– Checking/Replacing the Filter Insert
X
a
– Checking of the wear and tear of the vacuum vanes
X
a

User manual E by SIPLACE 7 Maintenance
From software version SC 712.1 Edition 05/2019 7.3 Maintenance on SIPLACE CP14 P
319
7.3 Maintenance on SIPLACE CP14 P
7
SIPLACE CP14 Every 6
months
Every 12
months
– Maintenance Pressure Control Valve
X
– Cleaning the Z Axis
X
– Oiling the DP Segment Guide
X
– Oiling the Z Axis Linear Guide
X
– Oiling the DP Driver Bearing
X
– Checking/Replacing the Vacuum-Conducting Parts
– Reflecting ring and cover
or 7
– Holding circuit and silencer
X
– Cleaning the Raceway and the Jaw
X
– Replacing the Filter Disks
X
– Checking/Cleaning/Replacing the Switching Disks
X
– Cleaning the Component Sensor
X