2.1 Safety instructions From software version SC 712.1 Edition 05/2019
36
2.1.2 Qualified personnel
Qualified personnel means that these people are familiar with the setting up, operation and
cleaning and checking of placement machines and add-on devices and are suitably qualified, e.g.
– have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
– have been trained or instructed in the upkeep and use of appropriate safety equipment in ac-
cordance with normal safety standards.
– Have received first aid training.
2.1.3 Important notes on operational safety
The following points MUST be observed in order to maintain operational safety:
2.1.3.1 General
The operational safety of SMD placement machines can be guaranteed only if the system is
used as prescribed and in accordance with the instructions in the user manual.
Always follow any safety regulations specific to your country.
Make sure that the warning labels are always clearly identifiable and always easily readable.
Replace any damaged warning or notice labels. Replace any labels that are missing.
The machine key for releasing the covers on the machine must be kept in a safe place where
it is only accessible to qualified personnel.
2
2
ASM Assembly Systems Singapore Pte ltd will not accept liability for any damage or conse-
quential damage that is the result of unauthorized/incorrect work.
If particularly hazardous situations are identified while the machine is in use, the machine
owner must immediately notify the manufacturer in writing so that appropriate action can be
taken to reduce the potential danger.
PLEASE NOTE
Owner's responsibility
The machine owner, and only the machine owner, is responsible for the safekeeping of
the machine key and for ensuring that it is handed over to authorized persons.

User manual E by SIPLACE 2 Operational safety
From software version SC 712.1 Edition 05/2019 2.1 Safety instructions
37
2
2.1.3.2 Safety of operators and other persons
Machine operators must only carry out work for which they have been adequately qualified
and with which they are totally familiar.
NEVER open one of the protective covers if you are not totally familiar with the use and func-
tioning of the machine! Do not open the protective covers during operation unless you are told
to do so in this manual or in the station software dialog.
NEVER place your head or arms in the gantry and lifting table traveling range while the station
is switched on!
For your own safety, wear work clothes that conform to the guidelines of the professional as-
sociation, i.e. no wide sleeves etc.
Reduce the risks by not wearing scarves, chains or ties at your work post.
People with long hair must wear a protective head covering.
2
WARNING
Severe injuries and damage to equipment in the case of incorrect usage!
In the event of the machine being incorrectly used, movement of the gantries or lifting ta-
bles, for example, can lead to severe injuries and considerable damage to equipment.
Safe operation of the machine requires correct usage by qualified staff with observance
of all warnings.
Some work on the machine (e.g. setting up) requires training that goes beyond the scope
of this manual.
WARNING
Dangerous voltage levels!
The system is electrically driven. Certain parts carry dangerous voltage levels.
There is a risk of death, severe injury and/or considerable damage to equipment if these
instructions are not followed.
Switch off at the main switch and disconnect the placement machine from the power
supply before carrying out any work on live components.
Lock the machine as described in section 2.10, page 95.

2 Operational safety User manual E by SIPLACE
2.1 Safety instructions From software version SC 712.1 Edition 05/2019
38
2.1.3.3 Safety of plant and equipment
Never make changes, however minor, unless you are totally aware of the effect they will have
on the overall functioning of the system.
The stations must always be set up, retooled and maintained by appropriately qualified per-
sonnel.
Do not make modifications to the safety equipment. In particular, NEVER deactivate circuit-
breakers or remove safety devices. Safety instructions for laser units
Permission to operate components that are classified as lasers is withdrawn if
– Mechanical damage to the unit is observed, or
– Any work is done on the mechanical or electrical parts of the unit. Even damaged or miss-
ing screw locking paint on laser components (e.g. cover plates, fasteners, adjusting po-
tentiometer) counts as work.
– Only qualified personnel may replace laser components.
– Repairs to laser units are carried out at the ASM factory exclusively.
2.1.4 Safety instructions on permanent magnets
Powerful permanent magnets are used for the linear motors of the X and Y axes.
2
2
DANGER
Danger to life from powerful magnetic fields inside the machine!
When protective covers are opened inside the machine, the life of persons with the follow-
ing passive or active implants is put at risk:
– Pacemakers
– Defibrillators
– Insulin pumps etc.
At-risk people must not stand in the immediate vicinity of the machine.
WARNING
DANGER OF CRUSHING!
There is a danger of crushing for persons with passive metal implants (e.g. plates,
screws).
Never reach into the machine when the protective covers are open and do not bend
over the open machine.
Do not bring any metal objects into the danger area.