User Manual E-by-SIPLACE 用户手册 - 第62页
2 Operational safety User manual E by SIPLACE 2.2 Warning labels From software version SC 712.1 Edition 05/201 9 62 2.2.7 Warning label on the Cekon P lug 2 Fig. 2.2 - 13 Cekon plug – W207, on the Cekon plug 2 W207 in fi…

User manual E by SIPLACE 2 Operational safety
From software version SC 712.1 Edition 05/2019 2.2 Warning labels
61
2.2.6 Warning label on the vacuum pump
Fig. 2.2 - 12 Warning labels on the vacuum pump
– W206 on the vacuum pump
–W-Hot surface
2
W206 in fig. 2.2 - 12, page 61, item no. 03009345-01 (1 label on the vacuum pump).
Hot surface label in fig. 2.2 - 12, page 61, item no. 03031926-01 (1 label on the vacuum pump)
2
WARNING
Please observe the safety instructions in the user manual supplied.
W206
(W-Hot surface
DANGEROUS VOLTAGES!
The labeled parts are still live when the main power switch is off.
Disconnect the machine from the mains before servicing it.
NAFTA region: RISK OF ELECTRIC SHOCK OR BURN!
2
RISK OF BURNS FROM HOT SURFACE!
The filter housing of the vacuum pump can become hot during continuous
operation.
Take care when touching the filter housing.

2 Operational safety User manual E by SIPLACE
2.2 Warning labels From software version SC 712.1 Edition 05/2019
62
2.2.7 Warning label on the Cekon Plug
2
Fig. 2.2 - 13 Cekon plug
– W207, on the Cekon plug
2
W207 in fig. 2.2 - 13, page 62, item no. 03009346-01.
W207
2
2
MAIN POWER VOLTAGE!
Switch off the main power switch and wait 30 seconds until the capac-
itors have discharged.
NAFTA region: RISK OF ELECTRIC SHOCK OR BURN!

User manual E by SIPLACE 2 Operational safety
From software version SC 712.1 Edition 05/2019 2.2 Warning labels
63
2.2.8 Warning labels power supply unit
Fig. 2.2 - 14 Warning labels of the power supply unit position
(1) Position of the power supply (behind the cover)
– W206 on the position of the power supply
– W-High temperatures
– W- General warning
2
W206 in fig. 2.2 - 14, page 63, item no. 03009345-01.
W206
(1)
W-High temperatures
W-General warning
DANGEROUS VOLTAGES!
The labeled parts are still live when the main power switch is off.
Disconnect the machine from the mains before servicing it.
NAFTA region: RISK OF ELECTRIC SHOCK OR BURN!