Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.2 Infrastructure at the installation location
151
4.2 Infrastructure at the installation location
4
4.2.1 Recommendations for foundation quality
The floor on which the placement machine is installed must be firm and level, as dynamic forces
could cause vibrations when the placement machine is operated. The degree of vibration depends
on the construction of the foundation. The following are suitable provided that the floor loading pa-
rameters, etc., are not exceeded:
Reinforced concrete ceiling constructions, e.g. ceilings in production halls
Reinforced concrete floor slabs, e.g. concrete floors in production halls without a basement
Rooms with double floors, provided that a stable foundation is included in the space between
them. The same setup conditions apply to this intermediate foundation, which can be made
from steel girders or concrete.
4
4.2.1.1 Maximum ground levelness
The floor underneath the placement machine may not exceed an incline of 0.63%. This corre-
sponds to an incline of 5 mm over a distance of 800 mm (e.g. the width of a changeover table).
4.2.1.2 Machine weight and floor loading
The machine weight and floor loading values can be found in section 3.3.1, page 103.
PLEASE NOTE
Also observe the document "Network and compressed air configuration for SMD sys-
tems" (German+English, Item No. 00197548-xx), which is supplied with your SIPLACE
placement machine.
4 Setting up and commissioning Instruction manual SIPLACE CA4 V2
4.2 Infrastructure at the installation location From software version 713.0 Edition 12/2019
152
4.2.2 Compressed air supply
Fig. 4.2 - 1 Position of compressed air supply in the placement machine
(1) Installation position of compressed air supply in sector 1
(2) Installation position of the silencer unit in sector 3 (behind the cover)
(T) Direction of PCB conveyor
2
1
Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.2 Infrastructure at the installation location
153
4.2.2.1 Checking the compressed air supply
Check whether the compressed air supply complies with the prescribed machine specifications
(see table in section 3.2
, page 100).
Record the compressed air characteristics at the installation location.
4
WARNING
Risk of injuries!
Risk of injuries from pressurized compressed air lines.
NEVER detach compressed air lines while they are still pressurized.