4 Setting up and commissioning Instruction manual SIPLACE CA4 V2 4.2 Infrastructure at the installation location From software ve rsio n 713.0 Edition 12/2019 160 4.2.3.6 Mains connection - mains connection cable WITHOUT…

100%1 / 322
Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.2 Infrastructure at the installation location
159
Connect L1,L2, L3, N and PE to the mains connection terminals X94 (item 1) in fig. 4.2 - 4,
page 158
. Make sure that the connection terminal is not damaged when you insert the wire
into it.
4
Hand-tighten the cable fixture (item 2) in fig. 158, page158.
Make sure that the wires and the cable can not rub against anything or get trapped. Fix the
wires and cables into place with cable ties, if needed.
4.2.3.5 Mains connection - mains connection cable WITH plug (configuration 2)
The placement machine is supplied with an approx. 5 m mains connection cable WITH a CEE
plug, red 16 A (in accordance with IEC 60309).
4
4
Fig. 4.2 - 5 Assignment in the CEE plug
CAUTION
Pay attention to correct phase sequence!
Pay attention to correct phase sequence. Incorrect phase sequence could lead to mal-
functions and cause damage to the vacuum pump! Check the vacuum pump (s) for cor-
rect direction of running when putting the placement machine into action.
Check the PE connection on the placement machine for correct function.
WARNING
The mains connection cable may only be connected by a qualified electrician.
The mains connection cable may only be connected by a qualified electrician.
The regulations of the country in which the placement machine is operated apply.
PE
L1
L2
L3
N
4 Setting up and commissioning Instruction manual SIPLACE CA4 V2
4.2 Infrastructure at the installation location From software version 713.0 Edition 12/2019
160
4.2.3.6 Mains connection - mains connection cable WITHOUT plug (configuration 3)
The placement machine is supplied with an approx. 5m mains connection cable WITHOUT plug.
4
4
Fig. 4.2 - 6 Description of wires in the mains power cable
WARNING
The mains connection cable may only be connected by a qualified electrician.
The mains connection cable may only be connected by a qualified electrician.
The regulations of the country in which the placement machine is operated apply.
1 = (L1): Three-phase
2 = (L2): Three-phase
3 = (L3): Three-phase
4 = (N): neutral conductor
green/yellow = (PE): conductor
Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.2 Infrastructure at the installation location
161
4.2.4 Overview of the microfuses
4
Fig. 4.2 - 7 Overview of the microfuses
4
Fuse Components Electricity
[A]
Voltage [V]
F1 CSB supply 6,3 24
F2 SSK-Ready CSB 6,3 24
F3 Conveyor control 6,3 24
F4 Distributor power 2 6,3 24