00198382-03_UM_SIPLACE-CA4-V2_EN - 第161页

Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning From software version 713.0 Ed ition 12/2019 4.2 Infrastructure at the installation location 161 4.2.4 Overview of the microfuses 4 Fig. 4.2 - 7 Overview o…

100%1 / 322
4 Setting up and commissioning Instruction manual SIPLACE CA4 V2
4.2 Infrastructure at the installation location From software version 713.0 Edition 12/2019
160
4.2.3.6 Mains connection - mains connection cable WITHOUT plug (configuration 3)
The placement machine is supplied with an approx. 5m mains connection cable WITHOUT plug.
4
4
Fig. 4.2 - 6 Description of wires in the mains power cable
WARNING
The mains connection cable may only be connected by a qualified electrician.
The mains connection cable may only be connected by a qualified electrician.
The regulations of the country in which the placement machine is operated apply.
1 = (L1): Three-phase
2 = (L2): Three-phase
3 = (L3): Three-phase
4 = (N): neutral conductor
green/yellow = (PE): conductor
Instruction manual SIPLACE CA4 V2 4 Setting up and commissioning
From software version 713.0 Edition 12/2019 4.2 Infrastructure at the installation location
161
4.2.4 Overview of the microfuses
4
Fig. 4.2 - 7 Overview of the microfuses
4
Fuse Components Electricity
[A]
Voltage [V]
F1 CSB supply 6,3 24
F2 SSK-Ready CSB 6,3 24
F3 Conveyor control 6,3 24
F4 Distributor power 2 6,3 24
4 Setting up and commissioning Instruction manual SIPLACE CA4 V2
4.2 Infrastructure at the installation location From software version 713.0 Edition 12/2019
162
4
F5 Distributor power 1 6,3 24
F6 Fan gantry 1 / 4 6,3 24
F7 Fan gantry 2 / 3 6,3 24
F8 Blower Y axis 6,3 24
F9 Trailing 1 6,3 42
F10 Head supply 2 6,3 42
F11 Head supply 3 6,3 42
F12 Head supply 4 6,3 42
F13 Distributor and Vision 6,3 42
F14 Conveyor drives 6,3 42
F15 -- 6,3 27
F16 MCGU 3 6,3 27
F17 MCGU 2 6,3 27
F18 MCGU 1 6,3 27
F19 FCU 4 6,3 27
F20 FCU 3 6,3 27
F21 FCU 2 6,3 27
F22 FCU 1 6,3 27
F23 Head axis 4 6,3 160
F24 Head axis 3 6,3 160
F25 Head axis 2 6,3 160
F26 Head axis 1 6,3 160
PLEASE NOTE
Replacing the microfuses
Only replace the microfuses with approved fuse links!
Fuse Components Electricity
[A]
Voltage [V]