1.2.3 Placement machine serial number
The serial number of the placement machine can be found on the inside of the machine frame at
location 1.
1
Fig. 1.2 - 3 Position of typeplate with serial number
(T) Direction of PCB conveyor
(1) Typeplate
(1)

1 Introduction Instruction manual SIPLACE CA4 V2
1.2 Placement machine description From software version 713.0 Edition 12/2019
22
1.2.4 EC Declaration of conformity
The product described below:
1
Manufactured by
ASM Assembly Systems GmbH&Co.KG
Rupert-Mayer-Str. 44
81379 Munich 1
conforms to the regulations and standards listed in the EC Declaration of
Conformity provided.
1.2.5 Use as prescribed
The product may only be used for the areas of application specified in the catalogs and technical
descriptions i.e. for the placement of SMD components and may only be used together with the
third party devices and components recommended or approved by ASM Assembly Systems
GmbH & Co. KG. Use for a different or extended purpose is not prescribed.
In the case of incorrect usage, ASM Assembly Systems GmbH & Co. KG will not assume liability
for any damage which occurs and will not guarantee the correct and proper function of machine
components.
Use as prescribed also includes compliance with all the instructions in the instruction manual.
For the product to operate correctly and reliably, it must have been conveyed, stored, erected and
assembled correctly and must be operated and maintained with care.
Product
Placement machine
Type SIPLACE CA4 V2
Item no.: 519781

Instruction manual SIPLACE CA4 V2 1 Introduction
From software version 713.0 Edition 12/2019 1.2 Placement machine description
23
1.2.6 Failure to use as prescribed
Failure to use the product as prescribed can result in both danger to life and limb and material
damage. For this reason, used other than as prescribed is expressly prohibited. In the case of in-
correct usage,ASM Assembly Systems GmbH & Co. KG will not assume liability for any damage
which occurs and will not guarantee the correct and proper function of machine components.
Use of the placement machine other than as prescribed includes, for example
– Operation of the placement machine with safety equipment deactivated or removed.
– Operation of the placement machine when the component trolley or SIPLACE Wafer System
(SWS) is missing or not docked.
– Placement of components that do not meet the permitted specification.
– Use of component feeder modules that have not been approved.
– Use of unauthorized accessories and additional modules.
– Use of the placement machine by unqualified personnel.
– Operation of the placement machine without the "dummy feeder" as hand guard at the loca-
tions, if not every location is occupied with a feeder module.
– Operation of the placement machine without a hand guard on the board conveyor.
– Unclear allocation of electrical connecting cables to each placement machine and the in-
stalled options.
– If there are two or more people standing at a component trolley location at the same time
during the retrofit.
– Persons standing on the cover plates and protective hoods.
1.2.7 Noise emissions
1
Max. noise emissions 75 dB (A)