00198382-03_UM_SIPLACE-CA4-V2_EN - 第254页
6 Component handling Instruction manual SIPLACE CA4 V2 6.1 SIPLACE tape feeder modules for SIPLACE CA4 V2 From software version 713.0 Edition 12/2019 254 6.1.3 Feeder module adapter for the X-Series Item no. 001413 05-xx…

Instruction manual SIPLACE CA4 V2 6 Component handling
From software version 713.0 Edition 12/2019 6.1 SIPLACE tape feeder modules for SIPLACE CA4 V2
253
6.1.2 Linear Dipping Unit 2 X ( LDU 2 X)
Item no. 00117012-xx Linear dip module for flux / LDU 2 X
The LDU 2 X is a special feeder module, which can make flux available with a defined layer thick-
ness. This flux can be used to coat components, thereby improving their solder properties. The
LDU 2 X is set up on the changeover table in the same way as an X feeder module and is con-
trolled via the station software and line software.
For a detailed description, refer to the user guide "SIPLACE LDU 2 X".
6
Fig. 6.1 - 3 Linear Dipping Unit (LDU 2 X)
6.1.2.1 Technical data
Dimensions (L x W x H) 629 mm x 105 mm x 202 mm
Weight 11 kg
Current consumption 24 V dc bis 30 V dc, 2 A (60 W)
Max. noise emissions 61dB (A)
Temperature range (storage) Between -25°C and +55°C
Temperature range (operation) Between +18°C and +25°C
Humidity (storage) ≤ 95%
Humidity (operation) 30% - 75% (on average not > 45%)

6 Component handling Instruction manual SIPLACE CA4 V2
6.1 SIPLACE tape feeder modules for SIPLACE CA4 V2 From software version 713.0 Edition 12/2019
254
6.1.3 Feeder module adapter for the X-Series
Item no. 00141305-xx Adapter for X-Series feeder modules
Item no. 00141308-xx Adapter plate for reject conveyor
Item no. 00141310-xx Adapter plate for label presenter
6
The spectrum of X tape feeder modules has been extended to include the linear vibratory feeder,
the label presenter and the reject conveyor. With an adapter, you can also convert the S linear
vibratory feeder, label presenter and reject conveyor for use with CA4 V2 component trolleys. The
adapter performs electronic as well as mechanical functions: It converts the communication sig-
nals from the S feeder modules into signals conforming to the extended X-Series protocol. Addi-
tional functions, such as feeder module identification, have also been implemented.
6
PLEASE NOTE
S linear vibratory feeders, label presenters and reject conveyors can not be set up at
component trolleys if these are in the access range of a SpeedStar (C&P20).

Instruction manual SIPLACE CA4 V2 6 Component handling
From software version 713.0 Edition 12/2019 6.1 SIPLACE tape feeder modules for SIPLACE CA4 V2
255
6.1.3.1 Feeder module adapter with label presenter
6
Fig. 6.1 - 4 Feeder module adapter with label presenter
(1) Adapter for X-Series feeder modules (item no. 00141305-xx)
(2) Adapter plate for label presenter (item no. 00141310-xx)
(3) Label presenter
6.1.3.2 Feeder module adapter with linear vibratory feeder
6
6
PLEASE NOTE
Use of adapter plate
An adapter plate is supplied as standard with the adapter for CA4 V2 feeder modules:
The adapter plate should be used for component heights up to 16.5 mm.
Component heights between 16.5 mm and 25 mm are processed without an adapter
plate.