Instruction manual SIPLACE CA4 V2 7 Station extensions From software version 713.0 Ed ition 12/2019 7.1 Nozzle changer 289 7.1.3 Assembling the nozzle cha nger for the C&P20 M2 / CPP M The nozzle changers are fixed i…

100%1 / 322
7 Station extensions Instruction manual SIPLACE CA4 V2
7.1 Nozzle changer From software version 713.0 Edition 12/2019
288
7.1.2.6 Configuration example CPP for SIPLACE CA4 V2
Locations 1, 2, 3 and 4 can each accommodate up to two nozzle changers for the CPP head (item
1 in fig. 7.1 - 8
, page 288).
7
Fig. 7.1 - 8 Position of nozzle changer for the SIPLACE SpeedStar machine - configuration example (SIPLACE CA4
V2)
7
7
(1) Nozzle changer
(2) Nozzle changer row 2 (optional)
(3) SIPLACE MultiStar
PLEASE NOTE
The placement machine stops if magazines are missing
The safety circuit stops the placement machine if magazines are missing or not fitted cor-
rectly.
Use all magazine places.
(1)
(2)
(2)(1)
(2)(1)
(1)
(2)
(3)
(3)
(3)
(3)
Instruction manual SIPLACE CA4 V2 7 Station extensions
From software version 713.0 Edition 12/2019 7.1 Nozzle changer
289
7.1.3 Assembling the nozzle changer for the C&P20 M2 / CPP M
The nozzle changers are fixed in each case to the COT insert.
Align the nozzle changer so that the sloping side points towards the COT insert.
7
7.1.3.1 Notes on operation
When you fill a magazine with a certain nozzle type for the first time, attach an adhesive label
to identify the type.
7
Open the locking plate and place the nozzles in the nozzle holders.
Close the locking plate so that the nozzles cannot drop out of the magazines.
7
7
Programming the nozzle changer is described in the SIPLACE Pro instruction manual.
WARNING
Risk of head crashes with mixed configurations!
There is a risk of head crashes with mixed configurations.
Only install the corresponding nozzle changer for each placement head, with the
nozzle magazines for the respective placement head.
PLEASE NOTE
7
Fill the magazines outside the placement machine and only replace complete mag-
azines.
CAUTION
Filling up magazines!
Before you fill magazines, make sure that all the nozzles on the Collect&Place head
have
been returned to their magazines.
PLEASE NOTE
Risk of jamming!
If components fall onto magazines, there is a risk that the locking plate could jam.
Do not allow components to drop onto the magazines.
You should therefore regularly clean the magazines and free locations.
7 Station extensions Instruction manual SIPLACE CA4 V2
7.1 Nozzle changer From software version 713.0 Edition 12/2019
290
7.1.3.2 Changing the magazine
Press the lever (item 1 in fig. 7.1 - 9, page 291), to release the magazine from the balls of the
snap fasteners (item 5 in fig. 7.1 - 9
, page 291). Lift the magazine off the base.
7
WARNING
Risk of head crashes with protruding lever
Any lever that is protruding over the magazine (item 1 in fig 7.1 - 9
) can result in a head
crash.
You should therefore make sure that the lever does not protrude over the maga-
zines.