EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第122页
EUKYX 2-9 199-2100 2.5 Composition of Placement Nozzle Data 2. 5 Composition of Placement No zzle Dat a The set parameters are used to pl ace the no zzles ont o the specified position s on the head (Place Head / Noz No.)…

EUKYX
2-8199-2100
2.4 Composition of Control Data
D03 Transfer Speed Data
Items Ref. No.
Transportation speed SET (D03_01)
Transfer speed Carrier
Stage inside
Output
(D03_02)
Input CNVR Y POSN ARR spd set-up (D03_03)
Output CNVR Y POSN ARR spd set-up (D03_04)
Component Deviation
Control
Carrier
Stage inside
Output
(D03_05)
Control the stop position Carrier
Positioning 1
Positioning 2
Output
(D03_06)

EUKYX
2-9199-2100
2.5 Composition of Placement Nozzle Data
2.5 Composition of Placement Nozzle Data
The set parameters are used to place the nozzles onto the specified positions on the head (Place
Head/Noz No.).
Refer to “3.5 PL Head/Nozzle” in this chapter for the details of each item according to the
reference Nos. (Ref. Nos.).
E01 Nozzle Place Data
Items Ref. No.
Nozzle Place (E01)
Nozzle Stk 1 (E02)
Nozzle Stk 2 (E02)
2.6 Composition of Placement Feeder Location Data
The set parameters are used to determine which feeder slot Nos. (Fdr No.) various types of
components should be allocated to.
Component IDs (types of components to be allocated) must be specified for each individual feeder
bases.
Refer to 3.6 CMPNT PL in this chapter for the details of each item according to the reference
Nos. (Ref. Nos.).
F01 CMPNT PL Data
Items Ref. No.
Fdr No. (F01_01)
Component ID (F01_02)
C (Control Command) (F01_03)
Comment (F01_04)
Feeder Fixed (F01_05)
Feeder Alternate (F01_06)
Fdr No. (F01_07)
Component Library Comment (F01_08)
Dir [deg], Carrier Data Type, Width [mm] (F01_09)
Fd. Pitch [mm] (F01_10)
Used Parts (F01_11)
Nozzle Type (F01_12)
Reference
Reference

EUKYX
2-10199-2100
2.7 Composition of Placement Data
2.7 Composition of Placement Data
The set parameters are used to place the components (IDs in the placement feeder location data) on
the points with the specified coordinates in the designated direction.
One step is allocated for each component to be placed.
Refer to 3.7 Placement in this chapter for the details of each item.
G01 Placement Data
Items Ref. No.
Un (G01_01)
Offset Data (G02)
Offset (G02)
Unit Control (G02_01)
Offset
X [mm], Y [mm], Z [ ° ], H [mm]
(G02_02)
Unit PCB Fiducial (G02_03)
Recog Coord
X1, Y1, X2, Y2
(G02_04)
Fiducial Mark
FM1, FM2
(G02_05)
P-Data (G03)
PNo. (G03_01)
X [mm], Y[mm] (G03_02)
Z [ ° ] (G03_03)
H [mm] (G03_04)
Component ID (G03_05)
Fdr. No. (G03_06)
Symbol (G03_07)
C (G03_08)
Comment (G03_09)
O-Data (G04)
Ono. (G04_01)
X [mm], Y[mm] (G04_02)
Z [ ° ] (G04_03)
H [mm] (G04_04)
C (G04_05)
Comment (G04_06)
B-X, B-Y (G04_07)
Reference