EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第156页
EUKYX 2-43 199-2100 3.5 PL Head/Nozzle 3.5 PL Head / Nozzle (E0 1 ) N ozzle Pla ce Dat a When the [ No zzle P la ce] t ab is pressed in the "PL Head / Nozzl e" wi ndow , the foll owing tab sheet app ear s. Grap…

EUKYX
2-42199-2100
3.4 Control
(D03_01)
Transportation speed SET
Common : When selected, the transfer speed is set commonly to the machines in the line.
Individual : When selected, the transfer speed is set individually for each machine in the line.
(D03_02)
Transfer speed
Carrier, Stage inside, Output
Select the PCB transfer speed from the following items.
Std(Max) :When selected, the PCB is transferred at the standard speed.
-20% : When selected, the PCB is transferred at the speed 20% lower than the standard.
-40% : When selected, the PCB is transferred at the speed 40% lower than the standard.
-60% : When selected, the PCB is transferred at the speed 60% lower than the standard.
-80% : When selected, the PCB is transferred at the speed 80% lower than the standard.
Value Set : When selected, any speed level is set freely for the PCB transfer.
(D03_03)
Input CNVR Y POSN ARR spd set-up
It is not currently used.
(D03_04)
Output CNVR Y POSN ARR spd set-up
It is not currently used.
(D03_05)
Avoid comp deviation
Carrier, Stage inside, Output
The following items are set for “Reload”, “Stage Inside” and “Discharge”.
Speed 1 [mm/sec]
The PCB is transferred at the specified speed.
Speed 2 [mm/sec]
The PCB transferred at the Speed 1, is detected using the speed reduction sensor and the speed is
reduced to the “Speed 2”specified here in this text box.
Acceleration [G]
The acceleration to reach the speed specified in “Speed 1”is set in this text box.
(D03_06)
Stop position control
Carrier, Positioning 1, Positioning 2, Output
The following items are set for “Reload”, “Positioning 1”, “Center”, “Positioning 2”and “Discharge”.
Position [mm]
The distance from the position of PCB detected with stop sensor to PCB stop position is set in this
text box.
Position 2 [mm]
It is not currently used.

EUKYX
2-43199-2100
3.5 PL Head/Nozzle
3.5 PL Head/Nozzle
(E01) Nozzle Place Data
When the [Nozzle Place] tab is pressed in the "PL Head/Nozzle" window, the following tab sheet
appears.
Graphic
Development
F2B40
(E01_01) Nozzle Place
Head1 and 2
Nozzle No. 1 to 15
This data is used to allocate the nozzles to the specified positions (Nozzle Allocation Nos.) on the
heads.

EUKYX
2-44199-2100
3.5 PL Head/Nozzle
(E02) Nozzle Stk 1, 2 data
When the [Nozzle Stk 1] or [Nozzle Stk 2] tab is pressed on the "PL Head/Nozzle" window, the
following tab sheet appears.
Graphic
Development
F2B41
(E02_01) Nozzle Stk 1, 2
Address Stk Types 1 to 15
Using these parameters, the nozzles are housed in the specified positions (address stocker type) in
the nozzle stocker.
High : 1 to 15
Multi : 1 to 9