EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第168页

EUKYX 2-55 199-2100 3.7 Placement (G03_0 4) H [m m] The component pl acement hei ght can be correcte d. H Component PCB Reference Plane F2B52 When a parameter is set as "H" data i n the last line ( last step No…

100%1 / 327
EUKYX
2-54199-2100
3.7 Placement
(G03_03)
Z=theta [deg]
Set angles for component placement. The placement angles must be determined according to the
packaged posture of components on the tape feeder.
Example:
0 45 90 135 180 225 270 315
Front Side of Machine
Z=Theta
(Angle)
Feeder Bases #1
Packaged
Posture
User Direction
of Tape Feed
Packaged
Posture
User Direction
of Tape Feed
Feeder Bases #2
Rear Side of Machine
Packaged Posture of
Component on Feeder
Tape Feeder
PCB
Tape Feeder
0
90
180
270
F2B51
EUKYX
2-55199-2100
3.7 Placement
(G03_04)
H [mm]
The component placement height can be corrected.
H
Component
PCB
Reference Plane
F2B52
When a parameter is set as "H" data in the last line (last step No.), it becomes invalid because
"E" is set in the "C (Control Command)" text box.
(G03_05)
Component ID
Set component IDs in the text boxes.
(G03_06)
Fdr No.
Set the Nos. of the feeders loaded with components.
The feeder Nos. (Fdr Nos.) to be set here must be specified in the placement feeder location
data.
(G03_07)
Symbol
Use them to enter the characters written on the board, for wiring pattern, etc.
Max. 32 characters can be used to set.
Available characters are half-width alphabetical/numerical characters and symbols.
(a) The automatic operation is not affected by these comments.
(b) The comments can be used to check "Ref. No." printed on the upper surfaces of PCBs.
Note
Note
Note
EUKYX
2-56199-2100
3.7 Placement
(G03_08)
C
Enter some of the following control commands.
If a control command other than the following ones is used, the step becomes invalid.
- (Hyphen) : This command handles the steps as those for component placement.
S : This command invalidates the steps specified as those for component placement.
C : This command invalidates the steps specified as those for component placement.
Note: As for dispensers, these steps become valid.
D : This command handles the steps as those for component placement.
Note: As for dispensers, these steps become invalid.
E : This shows the end of the placement data (O). When placement data (O) is not
created, this shows the end of the steps in the placement data (P).
P, Q : This shows the end of the placement data (P) of a repetitive pattern program.
B : When the unit PCB BBR function (option) is used, set this control command for
P-No. 1. See Note (b).
0, 1, 2, 3, 4, 5, 6, 7, 8, 9: These control commands are used to enable the block sorting function.
See Note (a).
Note
(a) When the block sorting function is used in the following case, the productivity will be
improved because components are placed on the specified areas of unit PCBs.
It is required to change the nozzles in the nozzle stocker for component placement on
a certain unit PCB according to the repetitive pattern program.
(b) Do not set the B command in any lines except "P-No. 1".
(c) Confirm that "0" (zero) is set in the "X [mm]", "Y [mm]", "Z=theta [deg]", "H", and "Fdr
No." text boxes of the last line (last step No.) and set "E", "P", or "Q".
(G03_09)
Comment
Set a comment for each step No. Alphanumeric characters and symbols can be used. Up to 32
characters can be used.
(a) The automatic operation is not affected by these comments.
(b) The comments can be used to check "Ref. No." printed on the upper surfaces of PCBs.
Note
Note