EUKYX 3-12 199-2100 1.3 Editing of Component Library Data 1 .3. 2 Saving o f Component IDs The fol lowi ng descri bes how to sav e a newl y created fi le (component ID) or the e dit ed parameters of the component ID . ( …

100%1 / 327
EUKYX
3-11199-2100
1.3 Editing of Component Library Data
1.3 Editing of Component Library Data
1.3.1 "Component Library" Edit Window
Select the desired component ID in the "Selection of component ID" window and press the [Open]
button. The "Component Library Edit" window opens.
F2C13A
(a) When the "New" icon is pressed, a new window opens. Default parameters are set in
the new window.
(b) The displayed contents change according to the selected component shape.
F2C14A
Edit the component library data in each tab sheet.
Refer to “Volume 6 : Component Library” for the description of the component library data
items.
The standard component library data prepared by us cannot be edited. Before editing data in
a file, give another name to the file and save it, using (
) icon.
Note
Reference
Note
EUKYX
3-12199-2100
1.3 Editing of Component Library Data
1.3.2 Saving of Component IDs
The following describes how to save a newly created file (component ID) or the edited parameters
of the component ID.
(1) Press the [
(Save)] or the [ (Save As)] icon on the toolbar.
:Save
When pressed, this saves the edited component ID (file), replacing the original component
ID (file) with the current one. However, if the component ID is protected, it cannot be
overwritten. In this case, [
(Save)] icon is not displayed.
:Save As
When pressed, this saves a newly created file (data of a new component ID) or the edited
file with another name (component ID).
(2) Press the [
(Save)] icon.
(The active component library data is saved with the current component ID name, replacing
the original program with the active one.)
(3) Press the [
(Save As)] icon. (The "List of Component ID" window appears.)
F2C15
(4) Enter a new component ID name as a file name and press [Save] button in the “Save
Component Data” window.
(The data in the active edit window is saved as a file with the entered component ID name.)
Double-clicking the “Component ID:” text box opens the “Search” window.
F2C16
A component ID can be entered with the touch keypad for editing.
Procedure
Note
EUKYX
3-13199-2100
2. "Temp Chng Comp Lib" Window
2. "Temp Chng Comp Lib" Window
In these tab sheets, the component library parameters are changed temporarily.
Graphic
Development
F2C17