EUKYX 4-1 1 199-2100 2.3 "NozMng." T ab Sheet 2.3 "NozMn g. " T ab S heet The pic kup in forma tion by hea d / nozz le is d isp la yed. When the [ No zMng.] tab is pressed in the "MNG.D T . &quot…

100%1 / 327
EUKYX
4-10199-2100
2.2 "FdrMng." Tab Sheet
[1] Feeder No.
Shown are the feeder Nos.
[2] Total Comp.
Each text box shows the number of pickup actions for each individual nozzles.
[3] Total Hdlg Errors
The No. of total error times in the pick-up operation is displayed in this data box.
[4] Rate of Hdlg Err (%)
The percentage of the pick-up error total times to the pick-up total times, is displayed in this data
box.
[5] Total Errors
Each text box shows the total number of errors detected in [7] through [16].
[6] Rate of Error (%)
Each text box shows the percentage of the total number of errors per the number of picked
components.
[7] A:Comp. Missing
Each text box shows the total number of missing components detected by the linear measure
detection sensor for each individual feeders.
[8] B:Comp. Missing
Each text box shows the total number of missing components detected through recognition
operation for each individual feeders.
[9] C:Comp. Vertical
Each text box shows the total number of vertical component errors detected by the linear measure
detection sensor for each individual feeders.
[10] D:Comp. Recog.
Each text box shows the total number of errors detected through recognition operation for each
individual feeders.
[11] E:Comp. Thick
Each text box shows the total number of errors in component thickness detected by the linear
measure detection sensor for each individual feeders.
[12] F:Pick-up Diff
Each text box shows the total times of pick-up deviation in each feeder in the recognition
processing.
[13] G:Comp. Posture
Each text box shows the total times of front/rear judgement error or polarity error in each feeder in
the recognition processing.
[14] H:Meas. Error
Each text box shows the total times of measured value error in each feeder.
[15] K:Copla. Error
Each text box shows the total times of detected “Coplanarity Error” in each feeder. This error is
detected in the option attachment.
[16] L:Obv / Reverse
The No. of front/rear error times for each feeder detected using the linear measure, is displayed in
this data box.
[17] Shrtg. of Comp.
Each text box shows the total times of detected “Component Shortage” in each feeder.
[18] Update Date & Time for Each Feeder
Each test box shows the update date & time for each feeder.
EUKYX
4-11199-2100
2.3 "NozMng." Tab Sheet
2.3 "NozMng." Tab Sheet
The pickup information by head/nozzle is displayed.
When the [NozMng.] tab is pressed in the "MNG.DT." window, the following tab sheet appears
inside the window.
[1] [2] [3]
[4]
[6] [7]
[8] [9]
[10] [11] [12] [13] [14] [15] [16]
[17]
[5]
F2D10
(a) The displayed tab sheet will look different, depending on which option is selected.
(b) When one of the above buttons is pressed, the nozzle No. with the biggest parameter
under the selected button is displayed in the first line and nozzle Nos. having the
subsequent (second, third, fourth, ...) biggest parameters follow.
That is, parameters are re-arranged in order of error counts, making it easy to analyze
and improve production rate. When the [Noz.] button is pressed, the Nos. are
re-arranged in their initial order (Nozzle Nos.).
The “NozMng.” tab sheet is divided into windows displaying the operation information by nozzle
per head. The corresponding head window appears by pressing the button.
Note
EUKYX
4-12199-2100
2.3 "NozMng." Tab Sheet
[1] Nozzle No.
Shown are the nozzle Nos.
[2] Total Comp
Each text box shows the number of pickup actions for each individual nozzles.
[3] Total Hdlg Errors
The number of pick-up error total times is displayed in this data box.
[4] Rate of Hdlg Err (%)
The percentage of the pick-up error total times to the total pick-up times is displayed in this data
box.
[5] Total Errors
Each text box shows the total number of errors detected in [7] through [17].
[6] Rate of Error (%)
Each text box shows the percentage of the total number of errors per the number of picked
components.
[7] A:Comp. Missing
Each text box shows the number of missing components detected by the linear measure detection
sensor for each individual nozzles.
[8] B:Comp. Missing
Each text box shows the number of missing components detected through recognition operation for
each individual nozzles.
[9] C:Comp. Vertical
Each text box shows the number of vertical component errors detected by the linear measure
detection sensor for each individual nozzles.
[10] D:Comp. Recog
Each text box shows the number of errors detected through recognition operation for each
individual nozzles.
[11] E:Comp. Thick
Each text box shows the number of errors in component thickness detected by the linear measure
detection sensor for each individual nozzles.
[12] F:Pick-up Diff
Each text box shows the number of pickup difference errors detected in the recognition process for
each individual nozzles.
[13] G:Comp. Posture
Each text box shows the number of reversed component and polarity judgment errors detected in
the recognition process for each individual nozzles.
[14] H:Meas. Error
Each text box shows the total times of measured value error in each feeder.
[15] K:Copla. Error
Each text box shows the total times of detected “Coplanarity Error” in each feeder. This error is
detected in the option attachment.
[16] L:Obv / Reverse
The “judged front/rear error” for each nozzle, detected using the linear measure is displayed in this
data box.
[17] Nozzle Clear/Change Date