EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第206页

EUKYX 4-14 199-2100 2.4 "Handling/Plac." T ab Sheet [2 ] Component chuck [ ( ( * Z - ( *A +* B +* C +* G +* L ) ) / * Z ) × 1 0 0 ] ( % ) The va lue (%) i s determined b y the fol lowin g formu la. {# of Picks …

100%1 / 327
EUKYX
4-13199-2100
2.4 "Handling/Plac." Tab Sheet
2.4 "Handling/Plac." Tab Sheet
When the [Handling/Plac.] tab is pressed in the "MNG.DT." window, the following tab sheet
appears inside the window.
[1]
[2]
[3]
F2D12
[1] Z:Total components
Shown is the number of component picks.
*A:component missing[sensor]
Shown is the number of component missing errors detected by the component linear
measure detection sensor.
(Case: "NG" (No Good) in Component Recognition and Linear Measure Detection Sensor)
*B:component missing[recognition]
Shown is the number of component missing errors detected through component recognition
operation.
*C:component vertical[sensor]
Shown is the number of components judged "NG" (No Good) by the linear measure
detection sensor although they are judged "OK" through component recognition process.
*G:component posture[recognition]
Shown is the number of reversed component and polarity judgment errors detected in the
recognition process.
*L:obverse/reverse[sensor]
The "judged front/rear error" times for each feeder, detected using the linear measure, is
displayed in these data boxes.
*D:component recognition
Shown is the number of components judged “NG” (No Good) through recognition process.
*E:component thickness
Shown is the number of component thickness errors detected by the linear measure
detection sensor.
*F:pick-up difference
Shown is the number of components judged “NG” (No Good) through recognition process.
*H:measurement error
Shown is the number of measurement error.
*K:coplanarlty
Shown is the number judged error by coplanarity error detection.
This error is detected in the option attachment.
EUKYX
4-14199-2100
2.4 "Handling/Plac." Tab Sheet
[2] Component chuck
[((*Z-(*A+*B+*C+*G+*L))/*Z) × 100] (%)
The value (%) is determined by the following formula.
{# of Picks - (Counts in "A" + Counts in "B" + Counts in "C"+ Counts in "G" + Counts in "L")}
/ # of Pick100
[3] Component placement
[((*Z-(*A+*B+*C+*D+*E+*F+*G+*H+*K+*L))/*Z) × 100] (%)
The value (%) is determined by the following formula.
{# of Picks - (Counts in "A" + Counts in "B" + Counts in "C"+ Counts in "D"+ Counts in "E"+
Counts in "F"+ Counts in "G+ Counts in "H"+ Counts in "K" + Counts in "L")}/# of Picks×100
About Data Counting (Counting of "*A: component missing [sensor]" and "*B: component
missing [recognition]")
The machine stops in an error condition according to the number of times (the number of
continuous component missing errors to be counted to stop the machine in an error condition)
set in the "1" text box of "Error process" in the "Control Data" tab sheet of a "Component
Library" window.
In this case, the number of missing component errors is not added to the number of picks and
the number of chuck errors.
Note
EUKYX
4-15199-2100
3. "CRNT.PP.MNG.DT" Window
3. "CRNT.PP.MNG.DT" Window
This window enables the operator to confirm the production management data for the current
pattern program.
[2]
[1]
[3]
Graphic
Development
F2D13
[1] Tabs and Tab Sheets
There are three tab sheets for the "CRNT.PP.MNG.DT" window. When any tab is pressed, the
corresponding tab sheet appears.
Buttons Description
PP Prod. His. In this tab sheet, the automatic operation starting date and time and ending
date and time are recorded.
Mach.Prfrm. In this tab sheet, the device management result data is displayed.
Reference
Refer to “2.1 “Mach.Prfrm,” Tab Sheet for each item.
FdrMng. In this tab sheet, the pick-up data for each feeder is displayed.
Reference
Refer to “2.2 “FdrMng.” Tab Sheet for each item.
[2] [Clear] Button
When this button is pressed, all the data parameters are deleted in each tab sheet for the "CRNT.
PP.MNG.DT" window.
[3] Information on Totalization File Information