EUKYX 4-23 199-2100 3.2 "Mach.Prfrm," T ab Sheet [ 1 7] Lcl fi d.err (% of T ot al PEC recog. err) Shown are the total nu mber of recognition errors i n each u ni t PCB and the percentage of the detec ted error…

EUKYX
4-22199-2100
3.2 "Mach.Prfrm," Tab Sheet
[16]
[16]
[17]
[18]
[19]
F2D18
[16] Zones #1 to #5
1pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the first fiducial mark and the percentage
of the detected errors per total number of all errors detected by the PEC recognition
function.
2pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the second fiducial mark and the
percentage of the detected errors per total number of all errors detected by the PEC
recognition function.
3pt err (% of Total PEC Recog. err)
Shown are the total number of errors detected on the third fiducial mark and the percentage
of the detected errors per total number of all errors detected by the PEC recognition
function.

EUKYX
4-23199-2100
3.2 "Mach.Prfrm," Tab Sheet
[17] Lcl fid.err (% of Total PEC recog. err)
Shown are the total number of recognition errors in each unit PCB and the percentage of the
detected errors per total number of all errors detected by the PEC recognition function.
[18] Total PEC recognition errors
Shown is the total number of errors detected by the PEC recognition function.
The number of errors detected by the global PEC recognition function and the total number
of errors detected by the BBR recognition function are displayed.
[19] CPH (PCB transfer time included)
The placeable component quantity per hour including PCB transfer time.
Latest value:
The placeable component quantity per hour when the program pattern is produced at the
end.
Average value:
The placeable component average quantity per hour when the program pattern is being
produced.
Max value:
The placeable component maximum quantity per hour when the program pattern is being
produced.
CPH (Only placement time)
The placeable component quantity per hour excluding PCB transfer time.

EUKYX
4-24199-2100
3.3 "EdrMng." Tab Sheet
3.3 "EdrMng." Tab Sheet
[1]
[2]
[3] [4] [6]
[7] [8]
[5]
[9] [10] [11] [12] [13]
[14] [15] [16]
[19] [20] [21]
[22]
[17] [18]
F2D20