EUKYX 4-29 199-2100 4.1 "Feeder Message Rate" T ab Sheet [ 7 ] E:Comp. Thick Each te xt box shows the total n umber of errors in component th ickness detected by the li near measure detec tion sensor for ea ch …

100%1 / 327
EUKYX
4-28199-2100
4.1 "Feeder Message Rate" Tab Sheet
F2D22
[1] Feeder No. (Actual Fdr No.)
Shown are the feeder Nos.
[2] Component ID
Each text box shows the component IDs for each individual feeders.
[3] A:Comp. Missing
Each text box shows the total number of missing components detected by the linear measure
detection sensor for each individual feeders.
[4] B:Comp. Missing
Each text box shows the total number of missing components detected through recognition
operation for each individual feeders.
[5] C:Comp. Vertical
Each text box shows the total number of vertical component errors detected by the linear measure
detection sensor for each individual feeders.
[6] D:Comp. Recog
Each text box shows the total number of errors detected through recognition operation for each
individual feeders.
EUKYX
4-29199-2100
4.1 "Feeder Message Rate" Tab Sheet
[7] E:Comp. Thick
Each text box shows the total number of errors in component thickness detected by the linear
measure detection sensor for each individual feeders.
[8] F:Pick-up Diff
Each text box shows the total number of pickup difference errors detected in the recognition
process for each individual feeders.
[9] G:Comp. Posture
Each text box shows the total number of reversed component and polarity judgment errors detected
in the recognition process for each individual feeders.
[10] H:Meas. Error
The No. of measurement error total times for each feeder is displayed in this data box.
[11] K:Copla. Error
Each text box shows the total count of the "Copla. Error" detection in each feeder.
[12] L:Obv/Reverse
The "judged front/rear error" times for each feeder, detected using the linear measure, is displayed
in these data boxes.
[13] Feeder Message Rate
(Total Err / Total Comp.)
Each text box shows the rate of pickup errors (the number of pickup errors per number of picked
component) for each feeder.
EUKYX
4-30199-2100
4.2 "Nozzle Message Rate" Tab Sheet
4.2 "Nozzle Message Rate" Tab Sheet
The corresponding tab sheet enables the operator to view the nozzle management data for each
nozzle/head.
[1]
[2]
[3]
[4] [6]
[7] [8][5]
[9]
[10] [11] [12]
F2D24
(a) The displayed tab sheet will look different, depending on which option is selected.
(b) Pressing one of the buttons displays the data in descending order. This is the order of
error counts, making it easy to analyze and improve production rate. Pressing the [Nozzle
No.] button returns to the default display (Order of Nozzle No.).
The window to display the feeder pickup information per feeder base is divided
Pressing the [Fdr #1] or [Fdr #2] button displays the relevant feeder base window.
Note