EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第230页

EUKYX 5-6 199-2100 6. "RECOG IMAGE" Window 6 . "REC OG IM A GE " Window When the [ Disp . Recg img dt] button is pressed, the imag es of the component s and PCB i n the autom ati c operation are sa ve…

100%1 / 327
EUKYX
5-5199-2100
5. "Mach Info" Window
5. "Mach Info" Window
When the [Mach Info] button is pressed, the "Mach Info" window appears.
[2]
[3]
[1]
Graphic
Development
F2E5
[1] Detailed Display
Up to 5000 logs of the machine information will be displayed.
When the number of logs exceeds "5000", the old logs are deleted in the sequential order. That is,
the logs are updated.
[2] [Clear] Button
When pressed, this button deletes the error logs.
[3] [Back] and [Next] Buttons
When the [Next] button is pressed, the next page opens. Pressing the [Back] button opens the
previous page.
EUKYX
5-6199-2100
6. "RECOG IMAGE" Window
6. "RECOG IMAGE" Window
When the [Disp. Recg img dt] button is pressed, the images of the components and PCB in the
automatic operation are saved according to the "Recognized Image Save" settings.
Other recognition processing data is saved automatically. (Component Recognition Test, PEC
Recognition Test, Nozzle Recognition, Pocket
Recognition, Badmark (Option), 2-D Barcode (Option) and Various Jig Recognitions, etc.)
Refer to 4.2.2 Image Save” in "Chapter 1" for the details.
When the machine is currently set in a running mode other than "STOP" or "PAUSE", set the
machine in the "STOP" or the "PAUSE" mode and press the [Disp. Rcg img dt] button.
[1]
[2] [3]
[5]
[4]
Graphic
Development
F2E6
[1] [SelectProgram/] Button
When pressed, the list of the saved recognized image names is displayed.
Refer to 6.1 Recog Image List” for the details.
[2] [ (Selected pattern program name) ] Button
When pressed, the selected pattern program recognized image is displayed.
[3] Displayed Item Change Button
[CompRcgView] Button
When pressed, the component recognized image is displayed.
[PECRcgView] Button
When pressed, the PEC recognized image is displayed.
[OtherRcgView] Button
When pressed, the other recognized images such as teaching, are displayed.
Reference
Note
Reference
EUKYX
5-7199-2100
6. "RECOG IMAGE" Window
[4] Recognized Image Display Section
The saved recognized image data items are displayed in the four panes and the images are
displayed in order from the new one (Upper Left, Upper Right, Lower Left and Lower Right
in this order). When the recognized image to be checked is selected, the recognized image
window appears.
Refer to 6.2 “RECOG IMAGEConfirmation Window” for the details of the "Recog Image
Window".
[Delete] Button
When the [Delete] button for the recognized image to be deleted, is pressed, the deletion
confirmation window appears.
F2E7
[5] Page Change Button
[
] : When pressed, the previous page appears.
[
] : When pressed, the next page appears.
Reference