EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第241页
EUKYX 6-4 199-2100 3. "PP CHANGE" W indow [ 5] [F dr . Loc. Chk ] But ton Us ing thi s button, the feed er locati ons specified i n the Cmt PP and the feeder t ype are disp la yed. Refer to Cha pter 1 , “ 3 . “…

EUKYX
6-3199-2100
3. "PP CHANGE" Window
3. "PP CHANGE" Window
The "PP CHANGE" window appears.
[1]
[3]
[4]
[5]
[6]
[7]
[8]
[2]
Graphic
Development
F2F4A
[1] Cmt PP
The pattern program currently selected is displayed in this section.
[2] Pattern Program Select tabs
The data items displayed in "[3] Pattern Program List" are divided into the tab sheet items and
displayed.
[3] Pattern Program List
The registered pattern programs are displayed as a list.
[4] [Edit] Button, [Del] Button, [Search] Button, and [Noz Check] Button
[Edit] Button : When pressed, the pattern program selected in the "[3] Pattern Program
List" is edited.
[Del] Button : When pressed, the pattern program selected in the "[3] Pattern Program
List" is deleted.
[Search] Button : When pressed, the pattern program is searched from the Pattern Program
List.
[Noz Check] Button : When pressed, the deficient number of nozzles to be used for the
pattern program selected in the "[3] Pattern Program List" or nozzles
located on the machine are displayed.

EUKYX
6-4199-2100
3. "PP CHANGE" Window
[5] [Fdr. Loc. Chk] Button
Using this button, the feeder locations specified in the Cmt PP and the feeder type are displayed.
Refer to Chapter 1, “3. “Comp.Reload” Window”, [13] [Fdr.Loc.Chk.] button for the details of
the “Fdr.Loc.Chk.” window.
[6] [Setup all Line Select] Button
Using this button, the setup setting in the pattern program change is performed. Whether or not the
conveyor width, support pin or nozzle is changed, is set.
F2F5A
►
Prgm Change
PCB Count : Whether or not the number of PCBs to be produced is cleared, is set in this
selection box.
PP.M NG.DT : Whether of not the pattern program management data is cleared, is set in this
selection box.
►
Cnvr.Width
Whether or not the conveyor width is setup, is set in this selection box.
►
PCB Sup.Pins Chg.Noz.
Whether or not the support pins are changed automatically, is set in this selection box.
• Set
Select “Disable”, “Enable” or “Store” for the automatic exchange of support pins when changing
program.
Disable : The support pins are not changed automatically when changing program.
Enable : The support pins are changed automatically when changing program.
Storage : The support pins are stored when changing program.
• Same Plc Chk
Select “Disable” or “Enable” for the support pin arrangement check if the arrangement of the
support pins when changing program is same as the previous one.
Enable : The support pin arrangement check is performed if the arrangement of the
support pins when changing program is same as the previous one.
Disable : The support pin arrangement check is not performed if the arrangement of the
support pins when changing program is same as the previous one.
Reference

EUKYX
6-5199-2100
3. "PP CHANGE" Window
►
Noz.Chg.
The nozzle change operation is set in this selection box.
• Set
Select "Disable", "Enable" or "Store" for the nozzles to be replaced when changing program.
Disable : The nozzles are not replaced when changing program.
Enable : The nozzles are replaced when changing program.
Storage : The nozzles are stored when changing program.
• Multi Noz Chk
Select "Disable" or "Enable" for the multi nozzle ID check after replacing the
nozzle when
changing program.
Disable :
The multi nozzle ID is not checked after replacing the nozzle when changing
program.
Enable :
The multi nozzle ID is checked after replacing the nozzle when changing
program.
[7] [Prgm Chng] Button
When pressed, the pattern program is changed to the one selected in the “[3] Pattern
Program List ”.
[Line] Button
This button is pressed when the pattern program in all the machines in the line is to be
changed.
:
This shows that the pattern program in all the machines in the line is to be
changed.
:
This shows that the pattern program in the single specified machine is to be
changed.
When the line consists of a single machine, this button is not displayed.
[8] “PP Chng Rcl” Tab Sheet
The pattern program change history is displayed in this section. The editing, deleting, and changing
program are available from the pattern program change history list.
F2F6A
Note