EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第264页

EUKYX 6-27 199-2100 7.1 "Fdr Pick-up T ch" Window 7 . 1 . 1 Fdr P ick -up T ch ( 1 ) Press the [H ead S el] but to n on the “Fdr Pick-u p T ch “ wind ow . (2 ) Press t he [Blo ck Se l] but ton. (Select the appr…

100%1 / 327
EUKYX
6-26199-2100
7.1 "Fdr Pick-up Tch" Window
7.1 "Fdr Pick-up Tch" Window
In this window, the teaching is performed with the manual alignment operation using the PEC
recognition camera, for the offset data items to absorb the dispersion caused by each feeder’s
difference in characteristics, out of the offset data items related to the feeders component pick-up
operation on the feeder base.
Graphic
Development
F2F33
[1] [Head Sel] Button
The buttons showing each head are displayed as images.
Using these buttons, the head (PEC recognition camera) to be used in the teaching is selected.
[2] [Block Sel] Button
The buttons showing each feeder base are displayed as images.
Using these buttons, the block where the teaching is performed, is selected.
[3] Tape Feeder List
Selects the tape feeder to be taught from the selected block.
[4] Tch Skip Mode
Select “Disable“ or “Enable“ for teach skip mode.
Disable
: Teach skip mode is not used.
Enable : Teach skip mode is used. Teaching is not performed for the feeder that “Skip“ or
“Finished“ is displayed in the “Teaching“ column.
[5] [Activate] Button
When pressed, the "Manual Alignment" window appears for the selected tape feeder No.
[6] [Auto Tch] Button
Teaching for all tape feeders of selected block is performed automatically.
EUKYX
6-27199-2100
7.1 "Fdr Pick-up Tch" Window
7.1.1 Fdr Pick-up Tch
(1) Press the [Head Sel] button on the “Fdr Pick-up Tch“ window.
(2) Press the [Block Sel] button.
(Select the appropriate block and select the tape feeder where the teaching is performed).
(3) Press the [Activate] button.
(The window is changed to the manual alignment window for the selected tape feeder.)
F2F34
(4) Press the [Send Comp] button. (Find the place necessary on the tape).
(5) When the manual alignment is not required :
Press the [Prev Fdr.] or [Next Fdr.] button to perform the manual alignment for the other
tape feeder.
When the manual alignment is required :
Follow the steps (6) and later.
(6) Press the [Eye Match] button.
(Start the manual alignment operation from the position shown using an arrow).
F2F35
Procedure
EUKYX
6-28199-2100
7.1 "Fdr Pick-up Tch" Window
(7) Press the [
] button if necessary. (Check the nozzle pick-up position).
F2F36
(8) When the manual alignment operation is completed, press the [OK] button.
(In the case that the performed manual alignment is cancelled, press the [Cancel] button.)
(9) Press the [Save] button to save the manual alignment results.