EUKYX 6-75 199-2100 (5 ) Press the [ Teaching] butt on to se lec t the t eaching met hod. When the [E diti ng] butt on has been sele cte d , the editing operation is perf ormed base d on the sample data . P ress the [C o…

EUKYX
6-74199-2100
(2) Confirm that the component is in the yellow circle (frame).
When it is in the circle, press the [Yes] button. Otherwise, press the [No] button.
F2F101
(3) After clicking the upper left of the component image, click the lower right to place the
whole component image within a frame.
F2F102
(4) Make sure that the whole image is within the frame and press the [Fixed] button.
7.3 "COMP RCG" Test Window

EUKYX
6-75199-2100
(5) Press the [Teaching] button to select the teaching method.
When the [Editing] button has been selected, the editing operation is performed based on the
sample data. Press the [Complete] button to return to the component library teaching window.
F2F103
(6) Press the [Teach] button to start the mold teaching operation.
Make sure that the component image is within the frame with dot lines. If the component is out
of the frame, adjust it again.
F2F104
Note
Note
7.3 "COMP RCG" Test Window

EUKYX
6-76199-2100
(7) When the mold teaching is completed, check the data and press the [Fixed] button.
(If the component size or angle is not correct, press the [Modify] button to correct the
graphic image.)
To turn the graphic, click the coordinate graphic and drag either one of the arrow ends.
F2F105
(8) Press the [Teach] button to start the ball teaching operation.
F2F106
Note
7.3 "COMP RCG" Test Window