EUKYX-199-2100_G5S2_Instruction_Vol2_E - 第325页
EUKYX 6-88 199-2100 8. "PCB.CNT ." Window 8 . " PCB. CNT . " Windo w Thi s wi ndow enab les the operator to set the number of PCBs to be produced. [2] [1] Graphic Development F2F122 [ 1 ] PCB Count er…

EUKYX
6-87199-2100
7.5 "PU Pos Ofst Tch" Window
[9] [Re-Recogition] Button
After pressing this button, the recognition image is touched in the matching window to re-recognize
the pockets.
When the pocket recognition is unavailable due to the feeder type, the [Re-Recognition] button
is not displayed.
[10] [End] Button
Pressing this button displays the confirmation window to save teaching data.
[Yes] button: Teaching data is reflected to component library data and overwritten.
[No] button: The saving of teaching data is canceled.
• Re-Recognition Procedure
(1) Press the [Re-Recognition] button on the Matching Window.
(2) Touch the position around the pocket to be re-recognized.
(The graphic image is moved.)
• Teaching Procedure
(1) Press the [Fdr Select] button to select the feeder for which the teaching operation is
performed.
(2) Press the [Move & Adjust] button. (The move & adjust recognition window will be displayed
to enable the manual alignment operation).
(1)
(5)
(2)
(4)
Correction value of pickup position
(3)
F2F121
(3) Move the eccentric pick-up position of the subject for which the manual alignment operation
is performed, so that it is the center of the cross hairs using the image movement button in
the recognition window.
(4) Press the [OK] button to determine the position. (The teaching results are displayed in the
data boxes for the pick-up position corrected values.)
(5) Press the [Save] button. (The confirmation window for the data saving will be displayed).
• When [Yes] is pressed, the data is reflected on the component library data and saved.
• When [No] is pressed, the data saving operation is stopped.
Note
Procedure
Procedure

EUKYX
6-88199-2100
8. "PCB.CNT." Window
8. "PCB.CNT." Window
This window enables the operator to set the number of PCBs to be produced.
[2]
[1]
Graphic
Development
F2F122
[1] PCB Counter Stop Mode
PCB Counter Stop Mode
[Designate] Button:
When this button is selected and the produced PCBs reach the value set in "Count" text box,
the PCB intake is stopped and after all the PCBs in the machine are discharged, the machine
is automatically stopped.
[No Designate] Button
When this button is selected, the PCB counter stop mode is not used.
Count
The number of produced PCBs for each lane for stopping the machine using the PCB Counter
Stop Mode, is set in this group box.
The set count is displayed in the "Count" data box in the "AUTO. OPN" window.
[2] [Init Value] Button
When this button is pressed, the set value for the "PCB Counter Stop Mode" is returned to the initial
value.
Note

EUKYX
6-89199-2100
8. "PCB.CNT." Window
• PCB Counter Stop Procedure
(1) Display the "PCB.CNT." window.
(2) Set the "PCB Counter Stop Mode" to "Designate".
(3) Press the [Count] button to display the "Count" window and read the "Count" barcode in
the instruction sheet using the barcode reader attached to the machine. (The value read
with the barcode reader, will be displayed on the "Count" window).
F2F123
(4) Confirm the read value and when it is OK, press the [Set] button.
(5) Confirm that the read value has been entered in the "Count" data box.
When the value in the "Count" data box is re-set, press the [Count] button and change the set
value.
Procedure
Note